Shielding analysis of proton therapy accelerators: a demonstration using Monte Carlo-generated source terms and attenuation lengths
- PMID: 25811254
- DOI: 10.1097/HP.0000000000000280
Shielding analysis of proton therapy accelerators: a demonstration using Monte Carlo-generated source terms and attenuation lengths
Abstract
Monte Carlo simulations are generally considered the most accurate method for complex accelerator shielding analysis. Simplified models based on point-source line-of-sight approximation are often preferable in practice because they are intuitive and easy to use. A set of shielding data, including source terms and attenuation lengths for several common targets (iron, graphite, tissue, and copper) and shielding materials (concrete, iron, and lead) were generated by performing Monte Carlo simulations for 100-300 MeV protons. Possible applications and a proper use of the data set were demonstrated through a practical case study, in which shielding analysis on a typical proton treatment room was conducted. A thorough and consistent comparison between the predictions of our point-source line-of-sight model and those obtained by Monte Carlo simulations for a 360° dose distribution around the room perimeter showed that the data set can yield fairly accurate or conservative estimates for the transmitted doses, except for those near the maze exit. In addition, this study demonstrated that appropriate coupling between the generated source term and empirical formulae for radiation streaming can be used to predict a reasonable dose distribution along the maze. This case study proved the effectiveness and advantage of applying the data set to a quick shielding design and dose evaluation for proton therapy accelerators.
Similar articles
-
Source terms and attenuation lengths for estimating shielding requirements or dose analyses of proton therapy accelerators.Health Phys. 2013 Aug;105(2):128-39. doi: 10.1097/HP.0b013e31828c36f9. Health Phys. 2013. PMID: 23799497
-
Shielding of proton accelerators.Radiat Prot Dosimetry. 2011 Jul;146(4):414-24. doi: 10.1093/rpd/ncr237. Epub 2011 Jun 14. Radiat Prot Dosimetry. 2011. PMID: 21672935
-
Preliminary shielding assessment for the 100 MeV proton linac (KOMAC).Radiat Prot Dosimetry. 2005;115(1-4):569-72. doi: 10.1093/rpd/nci151. Radiat Prot Dosimetry. 2005. PMID: 16381787
-
Radiation protection at medical accelerators.Radiat Prot Dosimetry. 2001;96(4):393-406. doi: 10.1093/oxfordjournals.rpd.a006627. Radiat Prot Dosimetry. 2001. PMID: 11843088 Review.
-
Shielding high energy accelerators.Radiat Prot Dosimetry. 2001;96(4):359-71. doi: 10.1093/oxfordjournals.rpd.a006624. Radiat Prot Dosimetry. 2001. PMID: 11843085 Review.
Cited by
-
Monte Carlo Simulations of Neutron Ambient Dose Equivalent in a Novel Proton Therapy Facility Design.Int J Part Ther. 2020 Spring;6(4):29-37. doi: 10.14338/IJPT-19-00071.1. Epub 2020 Mar 12. Int J Part Ther. 2020. PMID: 32582817 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources