Review
. 2015 Apr;135(4):948-958.
doi: 10.1097/PRS.0000000000001125.

The cost effectiveness of the DIEP flap relative to the muscle-sparing TRAM flap in postmastectomy breast reconstruction

Affiliations
Review

The cost effectiveness of the DIEP flap relative to the muscle-sparing TRAM flap in postmastectomy breast reconstruction

Naveen M Krishnan et al. Plast Reconstr Surg. 2015 Apr.

Abstract

Background: The deep inferior epigastric perforator (DIEP) flap has gained notoriety because of its proposed benefit in decreasing donor-site morbidity but has been associated with longer operative times, higher perfusion-related complications, and increased cost relative to muscle-sparing free transverse rectus abdominis myocutaneous (TRAM) flaps. The authors performed the first cost-utility analysis examining the cost effectiveness of DIEP flaps relative to muscle-sparing free TRAM flaps in women who underwent mastectomy.

Methods: A comprehensive literature review was conducted using the MED- LINE, Embase, and Cochrane library databases to include studies directly comparing DIEP to muscle-sparing free TRAM flaps in matched patient cohorts. Eight studies were included, examining 740 DIEP flaps and 807 muscle-sparing free TRAM flaps. Costs were derived adopting both societal and third-party payer perspectives. Utilities were derived from a previous cost-utility analysis. Probabilities of clinically relevant complications were combined with cost and utility estimates to fit into a decision tree analysis.

Results: The overall complication rates were 24.7 percent and 21.8 percent for DIEP and muscle-sparing free TRAM flaps, respectively. The authors' baseline analysis using Medicare reimbursement revealed a cost decrease of $69.42 and a clinical benefit of 0.0035 quality-adjusted life-year when performing DIEP flap surgery relative to muscle-sparing free TRAM flap surgery, yielding an incremental cost-utility ratio of -$19,834.29. When using societal costs, the incremental cost-utility ratio increased to $87,800.

Conclusion: DIEP flaps are cost effective relative to muscle-sparing free TRAM flaps when patients are carefully selected based on perforator anatomy and surgery is performed by experienced surgeons.

PubMed Disclaimer

References

    1. Chen CM, Halvorson EG, Disa JJ, et al. Immediate postoperative complications in DIEP versus free/muscle-sparing TRAM flaps. Plast Reconstr Surg. 2007;120:1477–1482
    1. Allen RJ, Treece P. Deep inferior epigastric perforator flap for breast reconstruction. Ann Plast Surg. 1994;32:32–38
    1. Nahabedian MY, Dooley W, Singh N, Manson PN. Contour abnormalities of the abdomen after breast reconstruction with abdominal flaps: The role of muscle preservation. Plast Reconstr Surg. 2002;109:91–101
    1. Futter CM, Webster MH, Hagen S, Mitchell SL. A retrospective comparison of abdominal muscle strength following breast reconstruction with a free TRAM or DIEP flap. Br J Plast Surg. 2000;53:578–583
    1. Blondeel N, Vanderstraeten GG, Monstrey SJ, et al. The donor site morbidity of free DIEP flaps and free TRAM flaps for breast reconstruction. Br J Plast Surg. 1997;50:322–330

LinkOut - more resources