Replacing Insulin Glargine with Neutral Protamine Hagedorn (NPH) Insulin in a Subpopulation of Study Subjects in the Action to Control Cardiovascular Risk in Diabetes (ACCORD): Effects on Blood Glucose Levels, Hypoglycemia and Patient Satisfaction
- PMID: 25819531
- DOI: 10.1016/j.jcjd.2014.12.008
Replacing Insulin Glargine with Neutral Protamine Hagedorn (NPH) Insulin in a Subpopulation of Study Subjects in the Action to Control Cardiovascular Risk in Diabetes (ACCORD): Effects on Blood Glucose Levels, Hypoglycemia and Patient Satisfaction
Abstract
Objective: To ensure patient safety when replacing insulin glargine (IG) with neutral protamine Hagedorn (NPH) insulin and to determine differences in blood glucose control, frequency of hypoglycemia, insulin dosing, health resource utilization and quality of life between users of IG and NPH insulin.
Methods: A single-site, open-label, randomized, 6-month comparative study of 66 patients from the Action to Control Cardiovascular Risk in Diabetes (ACCORD) trial. Randomization was 1:1 to receive IG or NPH insulin. Data regarding blood glucose control, insulin dosage adjustment and recording of hypoglycemia episodes were obtained through telephone calls; office visits were conducted to measure weight, glycated hemoglobin, fasting plasma glucose and blood glucose profile. The Diabetes Treatment Satisfaction Questionnaire (DTSQ) was used to measure patients' satisfaction with their diabetes treatment.
Results: Rates of symptomatic hypoglycemia did not differ significantly between groups: 37.5±2.2 for the IG group and 31.1±2.1 for the NPH group. However, patients treated with NPH insulin had higher frequencies of severe hypoglycemia (6.1±0.9) compared with 2.7±0.6 for the IG group. A significant difference in changes in glycated hemoglobin (A1C) was observed between the groups: the mean ± standard error A1C decreases from baseline were -0.34%±0.11 for the IG group, vs -0.01%±0.10 for the NPH insulin group. The data obtained from the DTSQ showed greater treatment satisfaction in the IG group compared with the NPH insulin group.
Conclusions: Switching from IG to NPH insulin resulted in more than double the rate of severe hypoglycemias and led to decreased metabolic control. Greater treatment satisfaction was observed with IG, compared with NPH insulin, as measured by change from baseline in the DTSQ scores.
Keywords: A1C; A1c; NPH insulin; blood glucose; glargine insulin; glycémie; hypoglycemia; hypoglycémie; insuline NPH; insuline glargine; patient satisfaction; satisfaction des patients.
Copyright © 2015 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical