Comparative Study
. 2015 Jul;110(7):1014-21.
doi: 10.1038/ajg.2015.63. Epub 2015 Mar 31.

Chromoendoscopy for Surveillance in Inflammatory Bowel Disease Does Not Increase Neoplasia Detection Compared With Conventional Colonoscopy With Random Biopsies: Results From a Large Retrospective Study

Affiliations
Comparative Study

Chromoendoscopy for Surveillance in Inflammatory Bowel Disease Does Not Increase Neoplasia Detection Compared With Conventional Colonoscopy With Random Biopsies: Results From a Large Retrospective Study

E Mooiweer et al. Am J Gastroenterol. 2015 Jul.

Abstract

Objectives: Randomized trials demonstrated that chromoendoscopy is superior to white light endoscopy with random biopsy sampling (WLE) for the detection of dysplasia in patients with inflammatory bowel disease (IBD). Whether implementing chromoendoscopy can increase the detection of dysplasia in clinical practice is unknown.

Methods: Patients with ulcerative colitis (UC) and Crohn's disease (CD) undergoing colonoscopic surveillance between January 2000 and November 2013 in three referral centers were identified using the patients' medical records. In recent years, the use of high-definition chromoendoscopy was adopted in all three centers using segmental pancolonic spraying of 0.1% methylene blue or 0.3% indigo carmine (chromoendoscopy group). Previously, surveillance was performed employing WLE with random biopsies every 10 cm (WLE group). The percentage of colonoscopies with dysplasia was compared between both groups.

Results: A total of 440 colonoscopies in 401 patients were performed using chromoendoscopy and 1,802 colonoscopies in 772 patients using WLE. Except for a higher number of CD patients with extensive disease and more patients with a first-degree relative with colorectal cancer (CRC) in the chromoendoscopy group, the known risk factors for IBD-associated CRC were comparable between both groups. Dysplasia was detected during 48 surveillance procedures (11%) in the chromoendoscopy group as compared with 189 procedures (10%) in the WLE group (P=0.80). Targeted biopsies yielded 59 dysplastic lesions in the chromoendoscopy group, comparable to the 211 dysplastic lesions detected in the WLE group (P=0.30).

Conclusions: Despite compelling evidence from randomized trials, implementation of chromoendoscopy for IBD surveillance did not increase dysplasia detection compared with WLE with targeted and random biopsies.

PubMed Disclaimer

Comment in

Similar articles

Cited by

References

    1. Gut. 2004 Feb;53(2):165-7 - PubMed
    1. Gastroenterology. 2007 Mar;132(3):874-82 - PubMed
    1. Am J Gastroenterol. 2014 May;109(5):715-22 - PubMed
    1. Am J Gastroenterol. 2008 Sep;103(9):2342-9 - PubMed
    1. Gastrointest Endosc. 2014 Mar;79(3):455-65 - PubMed

Publication types

MeSH terms

LinkOut - more resources