Current laboratory practices in flow cytometry for the enumeration of CD 4(+) T-lymphocyte subsets
- PMID: 25828263
- DOI: 10.1002/cyto.b.21241
Current laboratory practices in flow cytometry for the enumeration of CD 4(+) T-lymphocyte subsets
Abstract
Background: CD4(+) T-lymphocyte subset enumeration is routinely used for monitoring HIV disease progression, with approximately 300,000 tests performed annually in the UK alone. Technical variables can impact upon any laboratory test and therefore the final result obtained. Here, we report the findings of a survey questionnaire issued to 1,587 clinical flow cytometry laboratories to: (a) determine if the UK NEQAS for Leucocyte Immunophenotyping (UK NEQAS LI) lymphocyte subset external quality assessment (EQA) programme was suitable for current laboratory needs and practices; and (b) assess the impact of these responses on clinical practice where CD4(+) T-lymphocyte subsets analysis is undertaken. The survey covered areas not traditionally examined by EQA such as: staffing numbers, flow cytometer age and service intervals, plus six test specific sections covering: leukaemia immunophenotyping, CD4(+) T-lymphocyte subsets analysis (reported here), CD34(+) stem cell testing, low level leucocyte enumeration, minimal residual disease testing and PNH testing.
Results: The responses revealed major methodological variations between centres undertaking CD4(+) T-lymphocyte subset analysis. Significant differences existed in basic laboratory practices such as: normal range derivation; pipetting techniques; instrument maintenance and units of reporting, all of which results in non-adherence to international guidelines.
Discussion: Despite the availability of international guidelines our survey highlighted a lack of concordance amongst laboratory techniques. Such variation could adversely impact on patient care and clinical trial data. Therefore, it is recommended centres undertaking flow cytometric CD4(+) T-lymphocyte subsets analysis urgently review their methodologies and normal ranges to ensure they are fit for purpose and meet current international guidelines.
Keywords: CD4+ T-lymphocyte; flow cytometry; standardization.
© 2015 International Clinical Cytometry Society.
Similar articles
-
Current international flow cytometric practices for the detection and monitoring of paroxysmal nocturnal haemoglobinuria clones: A UK NEQAS survey.Cytometry B Clin Cytom. 2017 Jul;92(4):266-274. doi: 10.1002/cyto.b.21368. Epub 2016 Apr 18. Cytometry B Clin Cytom. 2017. PMID: 26934069
-
UK NEQAS for leucocyte immunophenotyping: the first 10 years.J Clin Pathol. 2001 Jul;54(7):508-11. doi: 10.1136/jcp.54.7.508. J Clin Pathol. 2001. PMID: 11429420 Free PMC article. Review.
-
The Immunology Quality Assessment Proficiency Testing Program for CD3⁺4⁺ and CD3⁺8⁺ lymphocyte subsets: a ten year review via longitudinal mixed effects modeling.J Immunol Methods. 2014 Jul;409:82-90. doi: 10.1016/j.jim.2014.05.017. Epub 2014 Jun 7. J Immunol Methods. 2014. PMID: 24911327 Free PMC article.
-
Comparison of methodological data measurement limits in CD4⁺ T lymphocyte flow cytometric enumeration and their clinical impact on HIV management.Cytometry B Clin Cytom. 2013 Jul-Aug;84(4):248-54. doi: 10.1002/cyto.b.21094. Epub 2013 Apr 23. Cytometry B Clin Cytom. 2013. PMID: 23788473
-
Automation for clinical CD4 T-cell enumeration, a desirable tool in the hands of skilled operators.Cytometry B Clin Cytom. 2017 Nov;92(6):445-450. doi: 10.1002/cyto.b.21370. Epub 2016 Mar 30. Cytometry B Clin Cytom. 2017. PMID: 26990810 Review.
Cited by
-
Report of the results of the International Clinical Cytometry Society and American Society for Clinical Pathology workload survey of clinical flow cytometry laboratories.Cytometry B Clin Cytom. 2017 Nov;92(6):525-533. doi: 10.1002/cyto.b.21398. Epub 2016 Aug 3. Cytometry B Clin Cytom. 2017. PMID: 27363814 Free PMC article.
-
Promise, Progress, and Pitfalls in the Search for Central Nervous System Biomarkers in Neuroimmunological Diseases: A Role for Cerebrospinal Fluid Immunophenotyping.Semin Pediatr Neurol. 2017 Aug;24(3):229-239. doi: 10.1016/j.spen.2017.08.001. Epub 2017 Aug 12. Semin Pediatr Neurol. 2017. PMID: 29103430 Free PMC article. Review.
-
Measurement and Clinical Significance of Biomarkers of Oxidative Stress in Humans.Oxid Med Cell Longev. 2017;2017:6501046. doi: 10.1155/2017/6501046. Epub 2017 Jun 18. Oxid Med Cell Longev. 2017. PMID: 28698768 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials