Comparative Study
. 2015 Oct:17 Suppl 2:e751-64.
doi: 10.1111/cid.12310. Epub 2015 Apr 1.

Accuracy Comparison of Implant Impression Techniques: A Systematic Review

Affiliations
Comparative Study

Accuracy Comparison of Implant Impression Techniques: A Systematic Review

António H J Moreira et al. Clin Implant Dent Relat Res. 2015 Oct.

Abstract

Background: Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit.

Purpose: The aim of this study was to identify the most accurate impression technique and factors affecting the impression accuracy.

Material and methods: A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit. A total of 417 articles were identified; 32 were selected for review.

Results: All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique, and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in nine; six studies tested vinyl polysiloxane and one study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intraoral optical devices were compared in four studies.

Conclusions: The most accurate results were achieved with two configurations: (1) the optical intraoral system with powder and (2) the open technique with splinted squared transfer copings, using polyether as impression material.

Keywords: dental prosthesis; implant impression; implant misfit; impression accuracy; optical scanning.