Arterial pulse pressure variation suitability in critical care: A French national survey
- PMID: 25829311
- DOI: 10.1016/j.accpm.2014.08.001
Arterial pulse pressure variation suitability in critical care: A French national survey
Abstract
Objective: Arterial pulse pressure variation (PPV) has been used as an accurate index to predict fluid responsiveness. However, many confounding factors have been recently described. The aims of this study were to assess the conditions of applicability of PPV in intensive care units (ICU).
Study design: A one-day French national survey.
Patients and methods: A form assessing the suitability of PPV was completed by practitioners for each critically-ill patient included on a set day.
Results: Four hundred and sixty-five patients were included in 36 ICUs. A regular sinus rhythm was noted in 408 (88%) patients and the presence of an arterial line in 324 (70%) patients. One hundred and twenty-seven (27%) patients were mechanically ventilated without spontaneous breathing. Only six patients (1.3%) had no confounding factors modifying the threshold value of the PPV.
Conclusion: The incidence of ICU patients in whom PPV was suitable and without confounding factors were respectively 18% and 1.3% in this one-day French national survey.
Keywords: Critical care; Monitoring; Predicting fluid responsiveness; Pulse pressure variation; Survey.
Copyright © 2015 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.
Comment in
-
Pulse pressure respiratory variation to predict fluid responsiveness: From an enthusiastic to a rational view.Anaesth Crit Care Pain Med. 2015 Feb;34(1):9-10. doi: 10.1016/j.accpm.2015.02.002. Epub 2015 Mar 18. Anaesth Crit Care Pain Med. 2015. PMID: 25829308 No abstract available.
Similar articles
-
Evaluation of the knowledge base of French intensivists and anaesthesiologists as concerns the interpretation of respiratory arterial pulse pressure variation.Anaesth Crit Care Pain Med. 2015 Feb;34(1):29-34. doi: 10.1016/j.accpm.2014.06.001. Epub 2015 Mar 5. Anaesth Crit Care Pain Med. 2015. PMID: 25829312
-
Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure.Crit Care Med. 2008 Oct;36(10):2810-6. doi: 10.1097/CCM.0b013e318186b74e. Crit Care Med. 2008. PMID: 18766099
-
Clinical relevance of pulse pressure variations for predicting fluid responsiveness in mechanically ventilated intensive care unit patients: the grey zone approach.Crit Care. 2014 Nov 4;18(6):587. doi: 10.1186/s13054-014-0587-9. Crit Care. 2014. PMID: 25658489 Free PMC article.
-
Pulse pressure variation and ARDS.Minerva Anestesiol. 2013 Apr;79(4):398-407. Epub 2013 Jan 31. Minerva Anestesiol. 2013. PMID: 23370121 Review.
-
Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity.Curr Opin Crit Care. 2008 Jun;14(3):334-9. doi: 10.1097/MCC.0b013e3282fd6e1e. Curr Opin Crit Care. 2008. PMID: 18467896 Review.
Cited by
-
Use of 'tidal volume challenge' to improve the reliability of pulse pressure variation.Crit Care. 2017 Mar 21;21(1):60. doi: 10.1186/s13054-017-1637-x. Crit Care. 2017. PMID: 28320434 Free PMC article. Review.
-
Relationship between pulse pressure variation and stroke volume variation with changes in cardiac index during hypotension in patients undergoing major spine surgeries in prone position - A prospective observational study.J Anaesthesiol Clin Pharmacol. 2022 Oct-Dec;38(4):553-559. doi: 10.4103/joacp.JOACP_594_20. Epub 2022 Feb 8. J Anaesthesiol Clin Pharmacol. 2022. PMID: 36778833 Free PMC article.
-
Applicability of respiratory variations in stroke volume and its surrogates for dynamic fluid responsiveness prediction in critically ill patients: a systematic review of the prevalence of required conditions.Rev Bras Ter Intensiva. 2017 Jan-Mar;29(1):70-76. doi: 10.5935/0103-507X.20170011. Rev Bras Ter Intensiva. 2017. PMID: 28444075 Free PMC article.
-
Changes in pulse pressure variation induced by passive leg raising test to predict preload responsiveness in mechanically ventilated patients with low tidal volume in ICU: a systematic review and meta-analysis.Crit Care. 2025 Jan 9;29(1):18. doi: 10.1186/s13054-024-05238-x. Crit Care. 2025. PMID: 39789598 Free PMC article.
-
How to detect a positive response to a fluid bolus when cardiac output is not measured?Ann Intensive Care. 2019 Dec 16;9(1):138. doi: 10.1186/s13613-019-0612-x. Ann Intensive Care. 2019. PMID: 31845003 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical