Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Jun;17(6):902-8.
doi: 10.1093/europace/euv076. Epub 2015 Apr 2.

Implantable cardioverter-defibrillators and subsequent cancer risk: a nationwide population-based cohort study

Affiliations

Implantable cardioverter-defibrillators and subsequent cancer risk: a nationwide population-based cohort study

Susanne Bendesgaard Pedersen et al. Europace. 2015 Jun.

Abstract

Aims: Despite increasing use of implantable cardioverter-defibrillators (ICDs) and reports linking selected bio-implants with cancer, the cancer risk associated with implanted ICDs remains unknown. The objective of our study was to examine cancer risk among ICD recipients.

Methods and results: We conducted a population-based cohort study using medical registries covering the entire Danish population. We identified all first-time ICD recipients during the period of 2000-11 and determined their subsequent cancer incidence. Standardized incidence ratios (SIRs) were computed by comparing observed cancer incidence in the ICD cohort with expected cancer incidence based on national incidence rates according to age, sex, and year of diagnosis. A total of 6723 ICD recipients were followed for up to 12 years (median 2.8 years) and contributed a total of 23 254 person-years of follow-up. Compared with the general population, ICD recipients had a slightly elevated overall risk of cancer [SIR = 1.1 (95% confidence interval (CI): 1.0-1.2)]. This was driven by the cancer risk among patients with ischaemic heart disease (IHD) [SIR = 1.1 (95% CI: 1.0-1.3)], which, as expected, was particularly elevated for tobacco-related cancers [SIR = 1.4 (95% CI: 1.2-1.6)]. Importantly, ICD recipients without IHD were not at increased cancer risk [SIR = 1.0 (95% CI: 0.8-1.3)].

Conclusion: This nationwide population-based cohort study with up to 12-year follow-up did not indicate a causal relation between ICD implantation and cancer. However, more follow-up data are needed to entirely rule out risks for individual cancer types.

Keywords: Cancer; Cohort study; Epidemiology; Implantable cardioverter-defibrillators; Risk.

PubMed Disclaimer

Comment in

Publication types

MeSH terms