Corneal epithelial thickness mapping using Fourier-domain optical coherence tomography for detection of form fruste keratoconus
- PMID: 25840306
- DOI: 10.1016/j.jcrs.2014.06.043
Corneal epithelial thickness mapping using Fourier-domain optical coherence tomography for detection of form fruste keratoconus
Abstract
Purpose: To determine whether optical coherence tomography (OCT) epithelial mapping can improve the detection of form fruste keratoconus.
Setting: French National Eye Hospital, Paris 6 Pierre & Marie Curie University, Paris, France.
Design: Retrospective comparative study.
Methods: Eyes with normal corneas, form fruste keratoconus, moderate keratoconus, or severe keratoconus were assessed using Fourier-domain OCT (RTVue 5.5), scanning-slit corneal topography (Orbscan IIz), and rotating Scheimpflug camera (Pentacam Comprehensive Eye Scanner). Several parameters provided by the software or derived from elevation maps, OCT pachymetric maps, and OCT epithelium parameters were evaluated and compared between the 4 groups.
Results: The study involved 145 eyes. There were no significant differences in the keratometry (K) value, inferior-superior value, keratoconus index, central K index, and topographic keratoconus classification indices between the form fruste keratoconus group and the control group (P > .05). Form fruste keratoconic corneas had less epithelial thickness in the thinnest corneal zone than normal corneas, and greater epithelial thickness in the thinnest corneal zone than keratoconic corneas (P < .005). The epithelial thickness in the thinnest corneal zone in form fruste corneas was located inferiorly (P < .005) and corresponded with the zone of minimum epithelial thickness and maximum posterior elevation (P < .005). The receiver operating characteristic curve analysis showed good overall predictive accuracy of the epithelial thickness in the thinnest corneal zone, with a 52 μm threshold value for discriminating form fruste keratoconic corneas from normal corneas.
Conclusions: The epithelial thickness in the thinnest corneal zone and its location provided by the OCT epithelial mapping might be useful for the early diagnosis of form fruste keratoconus.
Financial disclosure: No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Subclinical keratoconus detection by pattern analysis of corneal and epithelial thickness maps with optical coherence tomography.J Cataract Refract Surg. 2016 Feb;42(2):284-95. doi: 10.1016/j.jcrs.2015.09.021. J Cataract Refract Surg. 2016. PMID: 27026454 Free PMC article.
-
Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis.Br J Ophthalmol. 2013 Dec;97(12):1554-9. doi: 10.1136/bjophthalmol-2013-303477. Epub 2013 Sep 30. Br J Ophthalmol. 2013. PMID: 24081501 Clinical Trial.
-
Distinguishing between contact lens warpage and ectasia: Usefulness of optical coherence tomography epithelial thickness mapping.J Cataract Refract Surg. 2017 Jan;43(1):60-66. doi: 10.1016/j.jcrs.2016.10.019. J Cataract Refract Surg. 2017. PMID: 28317679 Free PMC article.
-
Measuring the cornea: the latest developments in corneal topography.Curr Opin Ophthalmol. 2007 Jul;18(4):325-33. doi: 10.1097/ICU.0b013e3281ca7121. Curr Opin Ophthalmol. 2007. PMID: 17568210 Review.
-
Advanced anterior segment imaging in keratoconus: a review.Clin Exp Ophthalmol. 2018 Mar;46(2):122-132. doi: 10.1111/ceo.13108. Epub 2017 Dec 21. Clin Exp Ophthalmol. 2018. PMID: 29160595 Review.
Cited by
-
Role of Corneal Epithelial Measurements in Differentiating Eyes with Stable Keratoconus from Eyes that Are Progressing.Ophthalmol Sci. 2022 Nov 14;3(1):100256. doi: 10.1016/j.xops.2022.100256. eCollection 2023 Mar. Ophthalmol Sci. 2022. PMID: 36579337 Free PMC article.
-
Comparison of Corneal Epithelial Thickness Map Measured by Spectral Domain Optical Coherence Tomography in Healthy, Subclinical and Early Keratoconus Subjects.Med Hypothesis Discov Innov Ophthalmol. 2019 Summer;8(2):85-91. Med Hypothesis Discov Innov Ophthalmol. 2019. PMID: 31263718 Free PMC article.
-
Improved High-Frequency Ultrasound Corneal Biometric Accuracy by Micrometer-Resolution Acoustic-Property Maps of the Cornea.Transl Vis Sci Technol. 2018 Apr 11;7(2):21. doi: 10.1167/tvst.7.2.21. eCollection 2018 Apr. Transl Vis Sci Technol. 2018. PMID: 29670830 Free PMC article.
-
Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus.PLoS One. 2021 Jun 18;16(6):e0248350. doi: 10.1371/journal.pone.0248350. eCollection 2021. PLoS One. 2021. PMID: 34143790 Free PMC article.
-
Age- and sex-related differences in corneal epithelial thickness measured with spectral domain anterior segment optical coherence tomography among Egyptians.Medicine (Baltimore). 2017 Oct;96(42):e8314. doi: 10.1097/MD.0000000000008314. Medicine (Baltimore). 2017. PMID: 29049238 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources