Preliminary patient-reported outcomes analysis of 3-dimensional radiation therapy versus intensity-modulated radiation therapy on the high-dose arm of the Radiation Therapy Oncology Group (RTOG) 0126 prostate cancer trial
- PMID: 25847819
- PMCID: PMC4490066
- DOI: 10.1002/cncr.29362
Preliminary patient-reported outcomes analysis of 3-dimensional radiation therapy versus intensity-modulated radiation therapy on the high-dose arm of the Radiation Therapy Oncology Group (RTOG) 0126 prostate cancer trial
Abstract
Background: The authors analyzed a preliminary report of patient-reported outcomes (PROs) among men who received high-dose radiation therapy (RT) on Radiation Therapy Oncology Group study 0126 (a phase 3 dose-escalation trial) with either 3-dimensional conformal RT (3D-CRT) or intensity-modulated RT (IMRT).
Methods: Patients in the 3D-CRT group received 55.8 gray (Gy) to the prostate and proximal seminal vesicles and were allowed an optional field reduction; then, they received 23.4 Gy to the prostate only. Patients in the IMRT group received 79.2 Gy to the prostate and proximal seminal vesicles. PROs were assessed at 0 months (baseline), 3 months, 6 months, 12 months, and 24 months and included bladder and bowel function assessed with the Functional Alterations due to Changes in Elimination (FACE) instrument and erectile function assessed with the International Index of Erectile Function (IIEF). Analyses included the patients who completed all data at baseline and for at least 1 follow-up assessment, and the results were compared with an imputed data set.
Results: Of 763 patients who were randomized to the 79.2-Gy arm, 551 patients and 595 patients who responded to the FACE instrument and 505 patients and 577 patients who responded to the IIEF were included in the completed and imputed analyses, respectively. There were no significant differences between modalities for any of the FACE or IIEF subscale scores or total scores at any time point for either the completed data set or the imputed data set.
Conclusions: Despite significant reductions in dose and volume to normal structures using IMRT, this robust analysis of 3D-CRT and IMRT demonstrated no difference in patient-reported bowel, bladder, or sexual functions for similar doses delivered to the prostate and proximal seminal vesicles with IMRT compared with 3D-CRT delivered either to the prostate and proximal seminal vesicles or to the prostate alone.
Keywords: comparative effectiveness; patient-reported outcomes; quality of life; radiation therapy; technology assessment.
© 2015 American Cancer Society.
Comment in
-
Seduced by technology?Cancer. 2015 Jul 15;121(14):2300-2. doi: 10.1002/cncr.29358. Epub 2015 Apr 2. Cancer. 2015. PMID: 25847582 No abstract available.
References
-
- Beckendorf V, Guerif S, Le Prise E, et al. 70 Gy versus 80 Gy in localized prostate cancer: 5-year results of GETUG 06 randomized trial. Int J Radiat Oncol Biol Phys. 2011 Jul 15;80(4):1056–1063. - PubMed
-
- Zietman AL, DeSilvio ML, Slater JD, et al. Comparison of conventional-dose vs high-dose conformal radiation therapy in clinically localized adenocarcinoma of the prostate: a randomized controlled trial. JAMA. 2005 Sep 14;294(10):1233–1239. - PubMed
-
- Vergeer MR, Doornaert PA, Rietveld DH, Leemans CR, Slotman BJ, Langendijk JA. Intensity-modulated radiotherapy reduces radiation-induced morbidity and improves health-related quality of life: results of a nonrandomized prospective study using a standardized follow-up program. Int J Radiat Oncol Biol Phys. 2009 May 1;74(1):1–8. - PubMed
-
- Wang-Chesebro A, Xia P, Coleman J, Akazawa C, Roach M., 3rd Intensity-modulated radiotherapy improves lymph node coverage and dose to critical structures compared with three-dimensional conformal radiation therapy in clinically localized prostate cancer. Int J Radiat Oncol Biol Phys. 2006 Nov 1;66(3):654–662. - PubMed
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous