. 2015 Apr 7;10(4):e0123749.
doi: 10.1371/journal.pone.0123749. eCollection 2015.

The quality of sputum smear microscopy in public-private mix directly observed treatment laboratories in West Amhara region, Ethiopia

Affiliations

The quality of sputum smear microscopy in public-private mix directly observed treatment laboratories in West Amhara region, Ethiopia

Almaw Manalebh et al. PLoS One. .

Abstract

Ethiopia adopted Public-Private Mix Directly Observed Treatment Short Course Chemotherapy (PPM-DOTS) strategy for tuberculosis (TB) control program. Quality of sputum smear microscopy has paramount importance for tuberculosis control program in resource-poor countries like Ethiopia. A cross-sectional study was conducted to assess the quality of sputum smear microscopy in 37 Public-Private Mix laboratories in West Amhara, Ethiopia. The three external quality assessment methods (onsite evaluation, panel testing and blind rechecking) were employed. Onsite assessment revealed that 67.6% of PPM-DOTS laboratories were below the standard physical space (5 X 6) m2. The average monthly workload per laboratory technician was 19.5 (SD±2.9) slides with 12.8% positivity rate. The quality of Acid Fast Bacilli (AFB) staining reagents was sub-standard. The overall agreement for blind rechecking of 1,123 AFB slides was 99.4% (Kappa = 0.97). Reading of 370 AFB panel slides showed 3.5% false reading (Kappa = 0.92). Moreover, the consistency of reading scanty bacilli slides was lower (93%) compared to 1+, 2+ and 3+ bacilli. Based on blind rechecking and panel testing results, PPM-DOTS site laboratories showed good agreement with the reference laboratory. Physical space and qualities of AFB reagents would be areas of intervention to sustain the quality of sputum smear microscopy. Therefore, regular external quality assessment and provision of basic laboratory supplies for TB diagnosis would be the way forward to improve the quality of sputum smear microscopy services in PPM-DOTS laboratories.

PubMed Disclaimer

Conflict of interest statement

Competing Interests: The authors declare that they have no competing interests.

Similar articles

Cited by

References

    1. World Health Organization. Global tuberculosis report. WHO/HTM/TB/. 2014.08. Available: http://www.who.int/about/licensing/copyrightform/en/index.html.
    1. (FMOH) Federal Ministry of Health. Guidelines for Clinical and Programmatic Management of TB, TB/HIV and Leprosy in Ethiopia, 5th ed; 2013. Addis Ababa.
    1. World Health Organization. Global Tuberculosis Control Report. Geneva: WHO. 2012. Available: http://www.who.int/about/licensing/copyrightform/en/index.html
    1. (FMOH) Federal Ministry of Health. PPM-DOTS implementation guideline, August, Ethiopia. 2006; Addis Ababa.
    1. Private Sector Program. Ethiopia Integrating TB/HIV Services in Private Clinics in Ethiopia. 2009. Addis Ababa.