Colonization of Legionella species in Turkish baths in hotels in Alanya, Turkey
- PMID: 25850992
- DOI: 10.1007/s10661-015-4444-3
Colonization of Legionella species in Turkish baths in hotels in Alanya, Turkey
Abstract
This study evaluated the prevalence of Legionella species in water samples collected from Turkish baths in hotels in Alanya, Turkey, from August 2003 to September 2013. Water samples were collected in 100-mL sterile containers and then concentrated by filtration. Heat treatment was used to eliminate other microorganisms from the samples, which were then spread on Legionella-selective-buffered charcoal yeast extract alpha (BCYE-α) agar and on BCYE-α agar supplemented with glycine, vancomycin, polymyxin, and cycloheximide. Cysteine-dependent colonies were identified by latex agglutination. In total, 135 samples from 52 hotels with Turkish baths were evaluated. Legionella species were identified in 11/52 (21.2%) hotels and 18/135 (13.3%) samples. The most frequently isolated species was Legionella pneumophila, with most isolates belonging to serogroups 6 (55.6%) and 1 (22.2%). The colony count was <100 colony-forming units (CFU) mL(-1) in nine samples, from 100 to 1000 CFU mL(-1) in six samples, and >1000 CFU mL(-1) in three samples. These findings suggest that the hot water systems of Turkish baths in hotels must be viewed as a possible source of travel-associated Legionnaires' disease, and preventative measures should be put in place.
Similar articles
-
Colonization of Legionella species in hotel water systems in Turkey.J Travel Med. 2007 Nov-Dec;14(6):369-73. doi: 10.1111/j.1708-8305.2007.00146.x. J Travel Med. 2007. PMID: 17995531
-
[Legionella pneumophila in thermal pools of hot springs in the central Anatolian district].Mikrobiyol Bul. 2002 Jul-Oct;36(3-4):237-46. Mikrobiyol Bul. 2002. PMID: 12838656 Turkish.
-
[Evaluation of a Legionella outbreak emerged in a recently opening hotel].Mikrobiyol Bul. 2013 Apr;47(2):240-9. doi: 10.5578/mb.4353. Mikrobiyol Bul. 2013. PMID: 23621724 Turkish.
-
[Incidence and significance of Legionella in industrial air conditioning systems].Schriftenr Ver Wasser Boden Lufthyg. 1993;91:231-40. Schriftenr Ver Wasser Boden Lufthyg. 1993. PMID: 8235479 Review. German. No abstract available.
-
[Bacteriological and hygienic aspects of a drinking and bathing water study].Schriftenr Ver Wasser Boden Lufthyg. 1985;63:149-57. Schriftenr Ver Wasser Boden Lufthyg. 1985. PMID: 3929376 Review. German. No abstract available.
Cited by
-
Environmental surveillance of Legionella in tourist facilities of the Balearic Islands, Spain, 2006 to 2010 and 2015 to 2018.Euro Surveill. 2022 May;27(21):2100769. doi: 10.2807/1560-7917.ES.2022.27.21.2100769. Euro Surveill. 2022. PMID: 35621000 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources