Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2015 Jul;114(1):92-7.
doi: 10.1016/j.prosdent.2015.01.009. Epub 2015 Apr 7.

Comparison of a conventional and virtual occlusal record

Affiliations
Comparative Study

Comparison of a conventional and virtual occlusal record

Eneko Solaberrieta et al. J Prosthet Dent. 2015 Jul.

Abstract

Statement of problem: Conventional methods associated with many processes in dentistry are being replaced by methods that use digital technology. One of these processes is the making of occlusal records for the positioning of casts in a virtual articulator. Conventional interocclusal records and the articulator are being replaced by the virtual occlusal record and the virtual articulator.

Purpose: The purpose of this study was to validate a virtual procedure to locate the mandibular cast in a 3-dimensional (3D) spatial position and to verify the occlusal contact points in reference to the corresponding maxillary cast on a virtual articulator.

Material and methods: The conventional procedure was carried out by locating 6 sets of casts in maximal intercuspal position without any interocclusal record. Then, the occlusal contacts were determined with articulating paper. Subsequently, the occlusal relationships and stone cast were digitized with a 3D scanner. The occlusal contacts were compared with photographs and by superimposing these on screenshots of the software. Finally, the deviation of discrete points on the mandibular cast was calculated, and all the points of the occlusal surface were compared point by point.

Results: This study analyzed the main variables of the virtual occlusal record by using 3 current reverse engineering software packages. The results show a mean deviation of 0.069 mm from the virtual occlusion procedure and a mean standard deviation of 0.011 mm from all the points of the occlusal surface.

Conclusions: The main conclusion of this study was that the accuracy provided by a virtual occlusion procedure is greater than that of the traditional physical interocclusal record. Additionally, knowing the deviation of each alignment (best-fit operation or algorithm) is useful.

PubMed Disclaimer

Publication types