Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Jun 1:138:77-85.
doi: 10.1016/j.talanta.2015.02.016. Epub 2015 Feb 16.

Evaluation of vibrational spectroscopic methods to identify and quantify multiple adulterants in herbal medicines

Affiliations

Evaluation of vibrational spectroscopic methods to identify and quantify multiple adulterants in herbal medicines

Jeremy S Rooney et al. Talanta. .

Abstract

To counter the growth of herbal medicines adulterated with pharmaceuticals crossing borders, rapid, inexpensive and non-destructive analytical techniques, that can handle complex matrices, are required. Since mid-infrared (MIR), near infrared (NIR) and Raman spectroscopic techniques meet these criteria, their performance in identifying adulterants in seized weightloss herbal medicines is definitively determined. Initially a validated high pressure liquid chromatography methodology was used for reference identification and quantification of the adulterants sibutramine H2O·HCl, fenfluramine HCl and phenolphthalein. Of 38 products, only sibutramine and phenolphthalein were detected by HPLC. The spectroscopic measurements showed Raman was ill-suited due to sample burning and emission while NIR lacked adulterant selectivity. Conversely, MIR demonstrated apt identification performance, which manifested as spectrally meaningful separation based on the presence and type of adulterant during principal component analysis (test set validated). Partial least squares regression models were constructed from the MIR training sets for sibutramine and phenolphthalein - both models fitted the training set data well. Average test set prediction errors were 0.8% for sibutramine and 2.2% for phenolphthalein over the respective concentration ranges of 1.7-11.7% and 0.9-34.4%. MIR is apposite for the screening of anorectic and laxative adulterants and is the most viable technique for wider adulterant screening in herbal medicines.

Keywords: Anorectics; Mid-infrared; Near-infrared; Phenolphthalein; Raman; Sibutramine.

PubMed Disclaimer

Publication types

LinkOut - more resources