Do new materials improve acetabular fixation and reduce wear? Commentary on an article by David C. Ayers, MD, et al.: "radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement"
- PMID: 25878320
- DOI: 10.2106/JBJS.O.00167
Do new materials improve acetabular fixation and reduce wear? Commentary on an article by David C. Ayers, MD, et al.: "radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement"
Comment on
-
Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.J Bone Joint Surg Am. 2015 Apr 15;97(8):627-34. doi: 10.2106/JBJS.N.00605. J Bone Joint Surg Am. 2015. PMID: 25878306 Free PMC article. Clinical Trial.
Similar articles
-
Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.J Bone Joint Surg Am. 2015 Apr 15;97(8):627-34. doi: 10.2106/JBJS.N.00605. J Bone Joint Surg Am. 2015. PMID: 25878306 Free PMC article. Clinical Trial.
-
A Novel Method for Assessment of Polyethylene Liner Wear in Radiopaque Tantalum Acetabular Cups: Clinical Validation in Patients Enrolled in a Randomized Controlled Trial.J Arthroplasty. 2015 Dec;30(12):2354-9. doi: 10.1016/j.arth.2015.06.050. Epub 2015 Jul 2. J Arthroplasty. 2015. PMID: 26216229 Clinical Trial.
-
The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis.J Bone Joint Surg Am. 2011 Apr 20;93(8):716-22. doi: 10.2106/JBJS.J.00287. J Bone Joint Surg Am. 2011. PMID: 21508278 Clinical Trial.
-
The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis.Clin Orthop Relat Res. 2004 Dec;(429):6-16. Clin Orthop Relat Res. 2004. PMID: 15577460 Review.
-
Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty.J Bone Joint Surg Am. 2007 Dec;89(12):2779-86. doi: 10.2106/JBJS.G.00043. J Bone Joint Surg Am. 2007. PMID: 18056513 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical