. 2013 May-Aug;7(2):232-6.
doi: 10.4103/0259-1162.118971.

Airtraq(®) versus Macintosh laryngoscope: A comparative study in tracheal intubation

Affiliations

Airtraq(®) versus Macintosh laryngoscope: A comparative study in tracheal intubation

Geeta Bhandari et al. Anesth Essays Res. 2013 May-Aug.

Abstract

Background: The curved laryngoscope blade described by Macintosh in 1943 remains the most widely used device to facilitate tracheal intubation. The Airtraq(®) (Prodol Meditec S.A, Vizcaya, Spain) is a new, single use, indirect laryngoscope introduced into clinical practice in 2005. It has wan exaggerated blade curvature with internal arrangement of optical lenses and a mechanism to prevent fogging of the distal lens. A high quality view of the glottis is provided without the need to align the oral, pharyngeal and tracheal axis. We evaluated Airtraq and Macintosh laryngoscopes for success rate of tracheal intubation, overall duration of successful intubation, optimization maneuvers, POGO (percentage of glottic opening) score, and ease of intubation.

Materials and methods: Patients were randomly allocated by computer-generated random table to one of the two groups, comprising 40 patients each, group I (Airtraq) and group II (Macintosh). After induction of general anesthesia, tracheal intubation was attempted with the Airtraq or the Macintosh laryngoscope as per group. Primary end points were overall success rate of tracheal intubation, overall duration of successful tracheal intubation, optimization maneuvers, POGO score and ease of intubation between the two groups.

Results: We observed that Airtraq was better than the Macintosh laryngoscope as duration of successful intubation was shorter in Airtraq 18.15 seconds (±2.74) and in the Macintosh laryngoscope it was 32.72 seconds (±8.31) P < 0.001. POGO was also better in the Airtraq group 100% grade 1 versus 67.5% in the Macintosh group, P < 0.001. Ease of intubation was also better in the Airtraq group. It was easy in 97.5% versus 42.5% in the Macintosh group, P < 0.001.

Conclusion: Both Airtraq and Macintosh laryngoscopes are equally effective in tracheal intubation in normal airways. Duration of successful tracheal intubation was shorter in the Airtraq group which was statistically significant.

Keywords: Airtraq; airway; laryngoscope; macintosh; tracheal intubation.

PubMed Disclaimer

Conflict of interest statement

Conflict of Interest: None declared.

References

    1. Caplan RA, Posner KL, Ward RJ, Cheney FW. Adverse respiratory events in anesthesia: A closed claims analysis. Anesthesiology. 1990;72:828–33. - PubMed
    1. Cheney FW. The American Society of Anesthesiologists Closed Claims Project: What have we learned, how has it affected practice, and how will it affect practice in the future? Anesthesiology. 1999;91:552–6. - PubMed
    1. Peterson GN, Domino KB, Caplan RA, Posner KL, Lee LA, Cheney FW. Management of the difficult airway: A closed claims analysis. Anesthesiology. 2005;103:33–9. - PubMed
    1. Mort TC. Esophageal intubation with indirect clinical tests during emergency tracheal intubation: A report on patient morbidity. J Clin Anesth. 2005;17:255–62. - PubMed
    1. Mort TC. Emergency tracheal intubation: Complications associated with repeated laryngoscopic attempts. Anesth Analg. 2004;99:607–13. - PubMed

LinkOut - more resources