Patient-centered activity monitoring in the self-management of chronic health conditions
- PMID: 25889598
- PMCID: PMC4391303
- DOI: 10.1186/s12916-015-0319-2
Patient-centered activity monitoring in the self-management of chronic health conditions
Abstract
Background: As activity tracking devices become smaller, cheaper, and more consumer-accessible, they will be used more extensively across a wide variety of contexts. The expansion of activity tracking and personal data collection offers the potential for patient engagement in the management of chronic diseases. Consumer wearable devices for activity tracking have shown promise in post-surgery recovery in cardiac patients, pulmonary rehabilitation, and activity counseling in diabetic patients, among others. Unfortunately, the data generated by wearable devices is seldom integrated into programmatic self-management chronic disease regimens. In addition, there is lack of evidence supporting sustained use or effects on health outcomes, as studies have primarily focused on establishing the feasibility of monitoring activity and the association of measured activity with short-term benefits.
Discussion: Monitoring devices can make a direct and real-time impact on self-management, but the validity and reliability of measurements need to be established. In order for patients to become engaged in wearable data gathering, key patient-centered issues relating to usefulness in care, motivation, the safety and privacy of information, and clinical integration need to be addressed. Because the successful usage of wearables requires an ability to comprehend and utilize personal health data, the user experience should account for individual differences in numeracy skills and apply evidence-based behavioral science principles to promote continued engagement.
Summary: Activity monitoring has the potential to engage patients as advocates in their personalized care, as well as offer health care providers real world assessments of their patients' daily activity patterns. This potential will be realized as the voice of the chronic disease patients is accounted for in the design of devices, measurements are validated against existing clinical assessments, devices become part of the treatment 'prescription', behavior change programs are used to engage patients in self-management, and best practices for clinical integration are defined.
Similar articles
-
General Practitioners' Perceptions of the Use of Wearable Electronic Health Monitoring Devices: Qualitative Analysis of Risks and Benefits.JMIR Mhealth Uhealth. 2021 Aug 9;9(8):e23896. doi: 10.2196/23896. JMIR Mhealth Uhealth. 2021. PMID: 34383684 Free PMC article.
-
Experiences With Wearable Activity Data During Self-Care by Chronic Heart Patients: Qualitative Study.J Med Internet Res. 2020 Jul 20;22(7):e15873. doi: 10.2196/15873. J Med Internet Res. 2020. PMID: 32706663 Free PMC article.
-
The patient experience of patient-centered communication with nurses in the hospital setting: a qualitative systematic review protocol.JBI Database System Rev Implement Rep. 2015 Jan;13(1):76-87. doi: 10.11124/jbisrir-2015-1072. JBI Database System Rev Implement Rep. 2015. PMID: 26447009
-
The Role of Wearable Devices in Chronic Disease Monitoring and Patient Care: A Comprehensive Review.Cureus. 2024 Sep 8;16(9):e68921. doi: 10.7759/cureus.68921. eCollection 2024 Sep. Cureus. 2024. PMID: 39381470 Free PMC article. Review.
-
A critical review of consumer health devices for stress self-management.Stud Health Technol Inform. 2014;202:221-4. Stud Health Technol Inform. 2014. PMID: 25000056 Review.
Cited by
-
Effect of a 12-week non-contact exercise intervention on body composition and health-related physical fitness in adults: a pilot test.Phys Act Nutr. 2022 Sep;26(3):32-36. doi: 10.20463/pan.2022.0016. Epub 2022 Sep 30. Phys Act Nutr. 2022. PMID: 36353828 Free PMC article.
-
Feasibility of a continuous, multi-sensor remote health monitoring approach in persons living with neurodegenerative disease.J Neurol. 2022 May;269(5):2673-2686. doi: 10.1007/s00415-021-10831-z. Epub 2021 Oct 27. J Neurol. 2022. PMID: 34705114 Free PMC article.
-
Comparative validity of energy expenditure prediction algorithms using wearable devices for people with spinal cord injury.Spinal Cord. 2020 Jul;58(7):821-830. doi: 10.1038/s41393-020-0427-5. Epub 2020 Feb 4. Spinal Cord. 2020. PMID: 32020039 Free PMC article.
-
Efficacy of a Commercial Physical Activity Monitor in Longitudinal Tracking of Patients With Pulmonary Hypertension: A Pilot Study.Tex Heart Inst J. 2023 Oct 17;50(5):e227866. doi: 10.14503/THIJ-22-7866. Tex Heart Inst J. 2023. PMID: 37853911 Free PMC article.
-
The role of non-invasive devices for the telemonitoring of heart failure patients.Heart Fail Rev. 2021 Sep;26(5):1063-1080. doi: 10.1007/s10741-020-09963-7. Heart Fail Rev. 2021. PMID: 32338334 Free PMC article. Review.
References
-
- Fox S, Duggan M. Tracking for health. Pew Internet & American Life Project. 2013. http://www.pewinternet.org/2013/01/28/tracking-for-health. Accessed 29 Sept 2014.
-
- Wang T. Future of biosensing wearables. Rock Health. 2014. http://rockhealth.com/resources/rock-reports/future-biosensing-wearables. Accessed 29 Sept 2014.
-
- Sarasohn-Kahn J. Making sense of sensors: how new technologies can change patient care. California Healthcare Foundation. 2013. http://www.chcf.org/publications/2013/02/making-sense-sensors. Accessed 29 Sept 2014.
-
- Ledger D, McCaffrey D. How the science of human behavior change offers the secret to long-term engagement. Endeavour Partners 2014. http://endeavourpartners.net/assets/Endeavour-Partners-Wearables-and-the.... Accessed 8 Oct 2014.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials