Biased visualization of hypoperfused tissue by computed tomography due to short imaging duration: improved classification by image down-sampling and vascular models

Affiliations
Comparative Study

Biased visualization of hypoperfused tissue by computed tomography due to short imaging duration: improved classification by image down-sampling and vascular models

Irene Klærke Mikkelsen et al. Eur Radiol. 2015 Jul.

Abstract

Objectives: Lesion detection in acute stroke by computed-tomography perfusion (CTP) can be affected by incomplete bolus coverage in veins and hypoperfused tissue, so-called bolus truncation (BT), and low contrast-to-noise ratio (CNR). We examined the BT-frequency and hypothesized that image down-sampling and a vascular model (VM) for perfusion calculation would improve normo- and hypoperfused tissue classification.

Methods: CTP datasets from 40 acute stroke patients were retrospectively analysed for BT. In 16 patients with hypoperfused tissue but no BT, repeated 2-by-2 image down-sampling and uniform filtering was performed, comparing CNR to perfusion-MRI levels and tissue classification to that of unprocessed data. By simulating reduced scan duration, the minimum scan-duration at which estimated lesion volumes came within 10% of their true volume was compared for VM and state-of-the-art algorithms.

Results: BT in veins and hypoperfused tissue was observed in 9/40 (22.5%) and 17/40 patients (42.5%), respectively. Down-sampling to 128 × 128 resolution yielded CNR comparable to MR data and improved tissue classification (p = 0.0069). VM reduced minimum scan duration, providing reliable maps of cerebral blood flow and mean transit time: 5 s (p = 0.03) and 7 s (p < 0.0001), respectively).

Conclusions: BT is not uncommon in stroke CTP with 40-s scan duration. Applying image down-sampling and VM improve tissue classification.

Key points: • Too-short imaging duration is common in clinical acute stroke CTP imaging. • The consequence is impaired identification of hypoperfused tissue in acute stroke patients. • The vascular model is less sensitive than current algorithms to imaging duration. • Noise reduction by image down-sampling improves identification of hypoperfused tissue by CTP.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Stroke. 2011 Dec;42(12 ):3435-40 - PubMed
    1. Comput Med Imaging Graph. 2008 Jan;32(1):67-77 - PubMed
    1. Invest Radiol. 1983 Jan-Feb;18(1):94-9 - PubMed
    1. Stroke. 2005 Jun;36(6):1153-9 - PubMed
    1. Magn Reson Med. 1996 Nov;36(5):715-25 - PubMed

Publication types

LinkOut - more resources