Biased visualization of hypoperfused tissue by computed tomography due to short imaging duration: improved classification by image down-sampling and vascular models
- PMID: 25894005
- DOI: 10.1007/s00330-015-3602-x
Biased visualization of hypoperfused tissue by computed tomography due to short imaging duration: improved classification by image down-sampling and vascular models
Abstract
Objectives: Lesion detection in acute stroke by computed-tomography perfusion (CTP) can be affected by incomplete bolus coverage in veins and hypoperfused tissue, so-called bolus truncation (BT), and low contrast-to-noise ratio (CNR). We examined the BT-frequency and hypothesized that image down-sampling and a vascular model (VM) for perfusion calculation would improve normo- and hypoperfused tissue classification.
Methods: CTP datasets from 40 acute stroke patients were retrospectively analysed for BT. In 16 patients with hypoperfused tissue but no BT, repeated 2-by-2 image down-sampling and uniform filtering was performed, comparing CNR to perfusion-MRI levels and tissue classification to that of unprocessed data. By simulating reduced scan duration, the minimum scan-duration at which estimated lesion volumes came within 10% of their true volume was compared for VM and state-of-the-art algorithms.
Results: BT in veins and hypoperfused tissue was observed in 9/40 (22.5%) and 17/40 patients (42.5%), respectively. Down-sampling to 128 × 128 resolution yielded CNR comparable to MR data and improved tissue classification (p = 0.0069). VM reduced minimum scan duration, providing reliable maps of cerebral blood flow and mean transit time: 5 s (p = 0.03) and 7 s (p < 0.0001), respectively).
Conclusions: BT is not uncommon in stroke CTP with 40-s scan duration. Applying image down-sampling and VM improve tissue classification.
Key points: • Too-short imaging duration is common in clinical acute stroke CTP imaging. • The consequence is impaired identification of hypoperfused tissue in acute stroke patients. • The vascular model is less sensitive than current algorithms to imaging duration. • Noise reduction by image down-sampling improves identification of hypoperfused tissue by CTP.
Similar articles
-
Perfusion computer tomography: imaging and clinical validation in acute ischaemic stroke.Brain. 2011 Nov;134(Pt 11):3408-16. doi: 10.1093/brain/awr257. Brain. 2011. PMID: 22075524
-
Admission CT perfusion is an independent predictor of hemorrhagic transformation in acute stroke with similar accuracy to DWI.Cerebrovasc Dis. 2012;33(1):8-15. doi: 10.1159/000331914. Epub 2011 Nov 30. Cerebrovasc Dis. 2012. PMID: 22143195 Free PMC article.
-
Comparison of computed tomography perfusion and magnetic resonance imaging perfusion-diffusion mismatch in ischemic stroke.Stroke. 2012 Oct;43(10):2648-53. doi: 10.1161/STROKEAHA.112.660548. Epub 2012 Aug 2. Stroke. 2012. PMID: 22858726
-
Penumbral imaging and functional outcome in patients with anterior circulation ischaemic stroke treated with endovascular thrombectomy versus medical therapy: a meta-analysis of individual patient-level data.Lancet Neurol. 2019 Jan;18(1):46-55. doi: 10.1016/S1474-4422(18)30314-4. Epub 2018 Nov 6. Lancet Neurol. 2019. PMID: 30413385
-
Brain perfusion CT in acute stroke: current status.Eur J Radiol. 2003 Mar;45 Suppl 1:S11-22. doi: 10.1016/s0720-048x(02)00359-5. Eur J Radiol. 2003. PMID: 12598022 Review.
Cited by
-
Iterative Reconstruction Improves Both Objective and Subjective Image Quality in Acute Stroke CTP.PLoS One. 2016 Mar 1;11(3):e0150103. doi: 10.1371/journal.pone.0150103. eCollection 2016. PLoS One. 2016. PMID: 26930290 Free PMC article.
-
Detecting CTP truncation artifacts in acute stroke imaging from the arterial input and the vascular output functions.PLoS One. 2023 Mar 30;18(3):e0283610. doi: 10.1371/journal.pone.0283610. eCollection 2023. PLoS One. 2023. PMID: 36996007 Free PMC article.
-
Differentiation of MS lesions through analysis of microvascular distribution.Imaging Neurosci (Camb). 2024 Nov 8;2:imag-2-00357. doi: 10.1162/imag_a_00357. eCollection 2024. Imaging Neurosci (Camb). 2024. PMID: 40800329 Free PMC article.
References
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical