. 1989 Dec;71(6):977-81.
doi: 10.1097/00000542-198912000-00022.

Inspiratory work and response times of a modified pediatric volume ventilator during synchronized intermittent mandatory ventilation and pressure support ventilation

Affiliations

Inspiratory work and response times of a modified pediatric volume ventilator during synchronized intermittent mandatory ventilation and pressure support ventilation

L D Martin et al. Anesthesiology. 1989 Dec.

Abstract

Volume ventilation by demand flow ventilators significantly increases work of breathing during inspiration. Although various ventilator modifications and different modes of ventilation have been developed, there have been few studies regarding imposed work of breathing in infants and children. This study was designed to evaluate several modifications of a commercially available demand flow ventilator designed to shorten response time (tr) and decrease the imposed work (Wi) involved in opening the demand valve. Minimum withdrawal volume (Vmin), maximum negative pressure (P mneg), and tr were measured. Wi was defined as the product of Vmin and P mneg. Seven Siemens Servo 900C ventilators were tested under 16 different trial conditions with four variables: 1) mode of ventilation (synchronized intermittent mandatory ventilation [SIMV] vs. pressure support ventilation [PSV]); 2) caliber of circuit tubing (adult vs. pediatric); 3) location of airway pressure monitor (distal vs. proximal); and 4) ventilator trigger sensitivity (0 cm H2O--high vs. -2 cm H2O--low). Vmin, Pmneg, and Wi were all decreased (P less than .05) while tr was unaffected by changing ventilator trigger sensitivity from low to high. Wi was decreased by pediatric tubing and proximal airway pressure monitoring only when low trigger sensitivity was used. PSV and proximal airway monitoring shortened tr. The authors conclude that the use of pediatric circuit tubing and proximal airway pressure monitoring with a Siemens Servo 900C ventilator significantly improved ventilator performance.