Study of the performance of 5 French and 7 French catheters in coronary angiography: a functional comparison
- PMID: 2590930
- DOI: 10.1002/ccd.1810180302
Study of the performance of 5 French and 7 French catheters in coronary angiography: a functional comparison
Abstract
The functional efficacy of a conventional 7F (high flow) coronary catheter (hand injection) was compared with a 5F (high flow) catheter using hand and powered injection in 29 patients with ischemic heart disease. Patients were randomized to 5F or 7F catheters as the initial catheter. Consecutive comparative coronary angiograms were performed in the 15 degrees right anterior oblique (RAO) view using Judkin's technique. Visual diagnostic grade (Grade 1 = Diagnostic, Grade 2 = Equivocal, Grade 3 = Nondiagnostic), vessel filling, vessel density (using a densitometer and corrected for background), streaming, and dislodgement were all evaluated independently by two experienced angiographers with correlation of results. Mean diagnostic grade (1.31 +/- 0.48) was significantly better with the 7F compared to 5F (hand) 1.72 +/- 0.81 and 5F (power) 2.00 +/- 0.71 (P less than or equal to 0.05) for each. Streaming was seen in 55% of injections with 5F (hand) versus 88.5% with 5F (power) and 20.7% with 7F. Measured vessel density was not different for the two catheters. Coronary injection dislodgement occurred significantly more often with 5F power injections than with hand injection of either catheter. Finally, in 6 (30%) of 20 patients in which the 5F was randomly the second catheter used, the operator had to revert to the 7F catheter in order to obtain adequate images. In conclusion, angiographic quality is reduced with 5F catheters compared to 7F high flow in certain patients. Thus, to achieve optimal diagnostic angiograms, larger lumen catheters may be required during certain procedures initially begun with 5F catheters.
Similar articles
-
Coronary angiography using 4 French catheters with power injection: a randomized comparison with 6 French catheters.Indian Heart J. 2002 Mar-Apr;54(2):184-8. Indian Heart J. 2002. PMID: 12086383 Clinical Trial.
-
Limitations in the use of five French coronary catheters.Int J Card Imaging. 1991;7(1):43-5. doi: 10.1007/BF01797679. Int J Card Imaging. 1991. PMID: 1753158 Clinical Trial.
-
Evaluation of new 4 French catheters by comparison to 6 French coronary artery images.J Invasive Cardiol. 1999 Jan;11(1):13-20. J Invasive Cardiol. 1999. PMID: 10745431
-
Percutaneous right brachial artery approach with 5F catheters for studying coronary artery disease.Cathet Cardiovasc Diagn. 1991 Jan;22(1):47-51. doi: 10.1002/ccd.1810220112. Cathet Cardiovasc Diagn. 1991. PMID: 1995175 Clinical Trial.
-
Use of slender catheters for transradial angiography and interventions.Indian Heart J. 2008 Jan-Feb;60(1 Suppl A):A22-6. Indian Heart J. 2008. PMID: 19359743 Review.
Cited by
-
3.3F catheter/sheath system for use in diagnostic neuroangiography.AJNR Am J Neuroradiol. 2002 Apr;23(4):711-5. AJNR Am J Neuroradiol. 2002. PMID: 11950674 Free PMC article.
-
Cardiac catheterisation with 5 French catheters.Br Heart J. 1991 Jul;66(1):114. doi: 10.1136/hrt.66.1.114-b. Br Heart J. 1991. PMID: 1854567 Free PMC article. No abstract available.
-
Balloon-assisted coiling through a 5-French system.Neuroradiology. 2007 Feb;49(2):157-9. doi: 10.1007/s00234-006-0163-3. Epub 2006 Dec 5. Neuroradiology. 2007. PMID: 17146636
-
Cardiac catheterisation with 5 French catheters.Br Heart J. 1990 Sep;64(3):211-3. doi: 10.1136/hrt.64.3.211. Br Heart J. 1990. PMID: 2206716 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources