Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Jun 1:991:68-78.
doi: 10.1016/j.jchromb.2015.04.009. Epub 2015 Apr 10.

Development of LC-MS/MS methodology for the detection/determination and confirmation of chloramphenicol, chloramphenicol 3-O-β-d-glucuronide, florfenicol, florfenicol amine and thiamphenicol residues in bovine, equine and porcine liver

Affiliations

Development of LC-MS/MS methodology for the detection/determination and confirmation of chloramphenicol, chloramphenicol 3-O-β-d-glucuronide, florfenicol, florfenicol amine and thiamphenicol residues in bovine, equine and porcine liver

Rick W Fedeniuk et al. J Chromatogr B Analyt Technol Biomed Life Sci. .

Abstract

A method for the detection and confirmation of organic solvent extractable residues of the neutral, acidic, and basic analytes of the amphenicol class veterinary drugs and selected metabolites was developed and validated. Using a modified QuEChERS extraction with SPE cleanup and LC-MS/MS analysis, limits of detection and confirmation for the different analytes in bovine, equine, and porcine liver ranged from 0.1ng/g for chloramphenicol to 1ng/g for florfenicol amine. Tissue homogenization with an ammonium formate/EDTA solution and subsequent analyte partitioning against 7:3 acetonitrile:isopropanol solution and mixed-mode strong-cation exchange solid-phase extraction cartridge cleanup allowed for the extraction of all compounds from tissues with mean recoveries ranging from 50% (chloramphenicol 3-O-β-d-glucuronide) to 90% (thiamphenicol). Matrix effects ranged from greater than 85% suppression for florfenicol amine to 70% matrix enhancement for chloramphenicol 3-O-β-d-glucuronide. Quantitation and confirmation were accomplished using commercially available penta-deuterated chloramphenicol as internal standard and multiple reaction monitoring (MRM) of two or three transitions per target analyte. Method accuracy was greater than 15% for all compounds except the glucuronide metabolite. Intra-lab method repeatability estimates ranged from 73% RSD for chloramphenicol 3-O-β-d-glucuronide to 14% RSD for chloramphenicol. Only chloramphenicol 3-O-β-d-glucuronide and florfenicol amine at the low end of their calibration ranges (0.25 and 1ng/g, respectively) did not meet AOAC recommended HorRatr guidelines for intra-lab repeatabilities. Preliminary tests show that the method's extraction protocol can be used to recover analytes of the β-agonists, corticosteroids, fluoroquinolones, sulfonamides, and tetracycline drug classes from the same matrices. Requirements for use in national chemical monitoring programs as a detection/confirmatory (florfenicol amine and chloramphenicol 3-O-β-d-glucuronide) and determinative/confirmatory (chloramphenicol, florfenicol, thiamphenicol) analytical methodology are met.

Keywords: Amphenicols; Chloramphenicol-glucuronide; Matrix effects; QuEChERS; Recovery.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources