Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2015 Aug;59(7):859-69.
doi: 10.1111/aas.12528. Epub 2015 Apr 24.

Variability in targeted arterial oxygenation levels in patients with severe sepsis or septic shock

Affiliations
Observational Study

Variability in targeted arterial oxygenation levels in patients with severe sepsis or septic shock

R M Dahl et al. Acta Anaesthesiol Scand. 2015 Aug.

Abstract

Background: Supplemental oxygen therapy is used for intensive care (ICU) patients with severe sepsis, but with no general guidelines and few safety data. The aim of this observational study was to describe the variability in oxygen administration as well as the association between partial pressure of arterial oxygen (PaO2 ) and mortality.

Methods: We extracted data from two Scandinavian clinical trials of ICU patients with severe sepsis or septic shock. We calculated average PaO2 and fraction of inspired oxygen (FiO2 ) from trial inclusion and the following 5 days, and assessed the association between PaO2 and 90-day mortality.

Results: The median PaO2 was 9.8 kPa [5-95% range 6.4-19.9] and FiO2 was 0.51 [5-95% range 0.27-1.00], respectively. Eight hundred and five of 1,770 patients (45%) died. The relative risk of mortality was 1.43 [95% CI: 1.19-1.65] in patients with average PaO2 < 8 kPa and 1.29 [95% CI: 0.84-1.68] in patients with average PaO2 ≥ 16 kPa, as compared to patients with average PaO2 10-12 kPa. The relative risk of mortality was 1.38 [95% CI: 1.17-1.58] in patients with an average FiO2 0.60-0.80 and 2.10 [95% CI: 1.88-2.23] in patients with an average FiO2 ≥ 0.80 as compared to patients with an average FiO2 ≤ 0.40.

Conclusion: Administration of oxygen in patients with severe sepsis resulted in a wide range of PaO2 . Significantly higher mortality was observed in patients with an average PaO2 < 8 kPa and FiO2 ≥ 0.60. The results do not imply causation and the associations between average PaO2 and adverse outcomes have to be assessed further.

PubMed Disclaimer

Publication types

LinkOut - more resources