Effects of stroke volume variation, pulse pressure variation, and pleth variability index in predicting fluid responsiveness during different positive end expiratory pressure in prone position
- PMID: 25936706
- DOI: 10.3881/j.issn.1000-503X.2015.02.008
Effects of stroke volume variation, pulse pressure variation, and pleth variability index in predicting fluid responsiveness during different positive end expiratory pressure in prone position
Abstract
Objective: To investigate the effects of different positive end expiratory pressures (PEEP) on functional hemodynamic parameters in patients lying in prone position during operation under general anesthesia.
Methods: Totally 60 patients undergoing cervical vertebra operation or lumbar vertebra operation were studied. All patients were also monitored with Vigileo/FloTrac system. The functional hemodynamic parameters including stroke volume variation (SVV), pulse pressure variation (PPV), and pleth variability index (PVI) under PEEP levels of 0 mmHg, 5 mmHg, 10 mmHg, and 15 mmHg were recorded before and after volume expansion (hydroxyethyl starch 6%,7 ml/kg). Fluid responsiveness was defined as an increase in stroke volume index (SVI) ≥ 15%(△SVI ≥ 15%). Responders were defined as patients demonstrating an increase in SVI ≥ 15% after intravascular volume expansion and non-responders as patients whose SVI changed <15%. Receiver operating characteristic (ROC) curves were generated for SVV, PPV, and PVI under different PEEP levels to determine their diagnosis accuracies and thresholds and their potential correlations.
Results: In the prone position, SVV, PPV, and PVI were significantly higher compared to those in the supine position (P<0.05) and the mean arterial pressure significantly decreased (P<0.05); however, the changes of heart rate, stroke volume, SVI, cardiac output, and cardiac index showed no significant difference (P>0.05). In the prone position, along with the elevation of PEEP (0 mmHg, 5 mmHg, 10 mmHg, and 15 mmHg), the areas under the ROC curves of SVV were 0.864, 0.759, 0.718, and 0.521, the area under the ROC of PPV were 0.873, 0.792,0.705, and 0.505, and the area under the ROC of PVI were 0.851, 0.765 ,0.709, and 0.512. Under PEEP=0 mmHg, the diagnostic thresholds of SVV, PPV, and PVI were 10.5, 11.5, and 13.5. Under PEEP=5 mmHg, the diagnostic thresholds of SVV,PPV, and PVI were 11.5,13.5, and 14.5.Under PEEP=10 mmHg,the diagnostic thresholds of SVV, PPV, and PVI were 13.5,14.5, and 16.5.In the prone position,there was a significant correlation between SVV,PPV,PVI,and PEEP.
Conclusions: SVV,PPV and PVI can predict fluid responsiveness similarly under the PEEP levels of 0,5, and 10 mmHg. Their diagnostic thresholds increases with the PEEP and the diagnostic accuracies decrease with the PEEP. However, under the PEEP level of 15 mmHg, SVV, PPV, and PVI can not predict fluid responsiveness accurately.
Similar articles
-
[A prospective clinical study of pleth variability index in prediction of volume responsiveness in patients with septic shock].Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2015 Jan;27(1):17-21. doi: 10.3760/cma.j.issn.2095-4352.2015.01.005. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2015. PMID: 25591431 Clinical Trial. Chinese.
-
[Stroke volume and pulse pressure variation are good predictors of fluid responsiveness in sepsis patients].Acta Med Croatica. 2013 Dec;67(5):407-14. Acta Med Croatica. 2013. PMID: 24979881 Croatian.
-
Validity of Pleth Variability Index to Predict Fluid Responsiveness in Patients Undergoing Cervical Spine Surgery in the Modified Prone Position.Medicina (Kaunas). 2024 Dec 7;60(12):2018. doi: 10.3390/medicina60122018. Medicina (Kaunas). 2024. PMID: 39768898 Free PMC article.
-
Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression.Crit Care. 2023 Nov 8;27(1):431. doi: 10.1186/s13054-023-04706-0. Crit Care. 2023. PMID: 37940953 Free PMC article.
-
A systematic review of pulse pressure variation and stroke volume variation to predict fluid responsiveness during cardiac and thoracic surgery.J Clin Monit Comput. 2017 Aug;31(4):677-684. doi: 10.1007/s10877-016-9898-5. Epub 2016 Jun 15. J Clin Monit Comput. 2017. PMID: 27306799
Cited by
-
A Randomised Controlled Study Comparing Pulse Pressure Variation (PPV) and Pleth Variability Index (PVI) for Goal-Directed Fluid Therapy Intraoperatively in Patients Undergoing Intracranial (Supratentorial ICSOLs) Surgeries.Rom J Anaesth Intensive Care. 2023 Apr 20;30(1):18-25. doi: 10.2478/rjaic-2023-0003. eCollection 2023 Apr. Rom J Anaesth Intensive Care. 2023. PMID: 37547491 Free PMC article.
-
Accuracy of stroke volume variation and pulse pressure variation in predicting fluid responsiveness undergoing one-lung ventilation during thoracic surgery: a systematic review and meta-analysis.Ann Transl Med. 2023 Jan 15;11(1):19. doi: 10.21037/atm-22-6030. Ann Transl Med. 2023. PMID: 36760241 Free PMC article.
-
Prediction of fluid responsiveness by dynamic preload parameters in children undergoing thoracoscopic surgery with one-lung ventilation - A prospective observational study.Medicine (Baltimore). 2022 Dec 9;101(49):e31795. doi: 10.1097/MD.0000000000031795. Medicine (Baltimore). 2022. PMID: 36626414 Free PMC article.
-
Development and perceived usability evaluation of an interactive smartphone application for the teaching of hemodynamics and evaluation of arterial pulse pressure variation.BMC Med Inform Decis Mak. 2023 Feb 9;23(1):31. doi: 10.1186/s12911-023-02131-5. BMC Med Inform Decis Mak. 2023. PMID: 36759835 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Medical