. 2015 Jun;26(2):129-33.
doi: 10.1007/s00399-015-0365-7. Epub 2015 May 5.

[The Wearable Cardioverter-Defibrillator (WCD)]

[Article in German]
Affiliations

[The Wearable Cardioverter-Defibrillator (WCD)]

[Article in German]
Thomas M Helms et al. Herzschrittmacherther Elektrophysiol. 2015 Jun.

Abstract

While the implantable cardioverter-defibrillator (ICD) has been proven to be the best choice for patients with long-term risk for sudden cardiac arrest/sudden cardiac death (SCA/SCD), the question is how to manage patients with only temporary risk, e.g., during the guidelines-recommended waiting period until the decision for an ICD can be made. These patient groups should be monitored around the clock to guarantee a lifesaving shock within a few minutes, if necessary.These conditions can be accomplished by the wearable cardioverter-defibrillator (WCD) in the outpatient sector. The WCD is worn on the skin and consists of four nonadhesive ECG electrodes as well as three defibrillation electrodes-two at the back and one at the front-embedded in a garment. The defibrillation unit is connected via a cord and can be worn over the shoulder or on a belt. Cardiac events can be recorded and retrospectively analyzed by the treating physician.The WCD is a safe and effective measure to terminate potentially lethal ventricular tachycardia and ventricular fibrillation. It may be used early after myocardial infarction with reduced left ventricular ejection fraction (LVEF), as well as for patients with acute heart failure in nonischemic cardiomyopathy with uncertain cause and prognosis. In addition, it may be used for patients waiting for heart transplantation, for patients who cannot be implanted an ICD due to comorbidities, and for patients after explantation of their ICD, e.g., because of infection until reimplantation.One may expect that risk stratification of patients with the WCD will lead to even better selection for ICD use.

PubMed Disclaimer

References

    1. Ann Intern Med. 2001 Mar 20;134(6):451-8 - PubMed
    1. J Am Coll Cardiol. 2013 Nov 19;62(21):2000-7 - PubMed
    1. Circ Arrhythm Electrophysiol. 2013 Feb;6(1):117-28 - PubMed
    1. Heart Rhythm. 2009 Jul;6(7):1085-104 - PubMed
    1. J Am Coll Cardiol. 2005 May 3;45(9):1397-405 - PubMed

MeSH terms

LinkOut - more resources