Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2015 Jul;150(1):84-8.
doi: 10.1016/j.jtcvs.2015.03.040. Epub 2015 Mar 31.

Five-year results of the pilot trial of a sutureless valve

Affiliations
Free article
Clinical Trial

Five-year results of the pilot trial of a sutureless valve

Bart Meuris et al. J Thorac Cardiovasc Surg. 2015 Jul.
Free article

Abstract

Objective: A prospective trial was designed to evaluate the feasibility of the Perceval sutureless aortic valve. We report the 5-year clinical and hemodynamic outcome.

Methods: A total of 30 patients (mean age: 80.4 ± 3.8 years; mean logistic European System for Cardiac Operative Risk Evaluation [euroSCORE]: 13.2 ± 7.3) received the valve in 3 European centers, between April 2007 and February 2008. Cumulative follow-up was 92.67 patient-years, with a median of 4.2 years. Patients with a small annulus were selected because only sizes 21 and 23 mm (covering annuli diameters from 19 to 23 mm) were available at this early stage of the trial. In 37% of the patients, a 21-mm valve was used; 63% received a 23-mm valve; 14 patients had concomitant coronary artery bypass grafting. Clinical and hemodynamic follow-up evaluation were performed annually, including echocardiography.

Results: Procedural success was 100%. Cardiopulmonary bypass time and cross-clamp time in isolated aortic valve replacement were 46.4 ± 6.7 minutes and 29.3 ± 8.0 minutes, respectively. One patient died during the hospital stay. Postoperative complications included 1 patient with mediastinal bleeding, and 1 with atrioventricular block that led to pacemaker implantation. No stroke occurred in either the early or late period. At the last available follow-up, 22 patients were alive. The mean gradient was 9.3 mm Hg, with an effective orifice area of 1.7 cm(2) at 5 years. No dislodgement, structural valve deterioration, hemolysis, or valve thrombosis was reported.

Conclusions: This study reports the first and longest experience with a truly sutureless valve, evaluating implantation feasibility and valve safety. Results from up to 5 years of follow up confirmed the performance and safety of this device, even in a medium- to high-risk patient population with a small aortic annulus.

Keywords: Aortic valve replacement; sutureless heart valve prosthesis.

PubMed Disclaimer

Comment in

Publication types

LinkOut - more resources