Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2015 Jun;42(1):70-2.
doi: 10.1016/j.gaitpost.2015.04.008. Epub 2015 Apr 24.

Free-living activity counts-derived breaks in sedentary time: Are they real transitions from sitting to standing?

Affiliations
Comparative Study

Free-living activity counts-derived breaks in sedentary time: Are they real transitions from sitting to standing?

Tiago V Barreira et al. Gait Posture. 2015 Jun.

Abstract

Background: Previous research has demonstrated a link between free-living accelerometer-measured breaks in sedentary time and health related variables. Breaks in sedentary time are typically inferred from time-stamped accelerometer data indicating a transition from lack of movement (recording of <100 activity counts/min) to relatively more movement (≥100 activity counts/min). However, it remains unknown whether these breaks actually represent sit-to-stand postural transitions in free-living. Thus, the purpose of this study was to compare free-living accelerometer-derived and posture-derived estimates of breaks in sedentary time using the ActiGraph GT3X+ (AG) and the activPAL™ (AP), respectively.

Methods: A total of 15 participants concurrently wore an AG at their waist and an AP on their right thigh for 7 consecutive days (24h/day - removing them only when in contact with water). Data from both devices were matched on minute-by-minute timestamps while also applying a 3-min allowance window to account for clock drift. Dependent t-test was used to evaluate differences in mean breaks between AG and AP.

Results: The AG detected 74±4.1 breaks/day (mean±SEM) while the AP detected 39±3.1 breaks/day (P<0.001). On average, the AG detected 67% of the AP breaks while 65% of the AG breaks did not correspond with AP breaks. Of the non-corresponding AG breaks, 52% occurred when participants were sitting, 42% when standing, and 6% when transitioning from standing to sitting.

Conclusion: The AG detected a significantly higher number of breaks in sedentary time, the majority of which do not correspond to sit-to-stand transitions as measured by the AP.

Keywords: Accelerometry; Agreement; Posture; Sitting; Validity.