High temporal resolution dynamic contrast-enhanced MRI using compressed sensing-combined sequence in quantitative renal perfusion measurement
- PMID: 25967586
- DOI: 10.1016/j.mri.2015.05.004
High temporal resolution dynamic contrast-enhanced MRI using compressed sensing-combined sequence in quantitative renal perfusion measurement
Abstract
Purpose: To demonstrate the feasibility of the improved temporal resolution by using compressed sensing (CS) combined imaging sequence in dynamic contrast-enhanced MRI (DCE-MRI) of kidney, and investigate its quantitative effects on renal perfusion measurements.
Materials and methods: Ten rabbits were included in the accelerated scans with a CS-combined 3D pulse sequence. To evaluate the image quality, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were compared between the proposed CS strategy and the conventional full sampling method. Moreover, renal perfusion was estimated by using the separable compartmental model in both CS simulation and realistic CS acquisitions.
Results: The CS method showed DCE-MRI images with improved temporal resolution and acceptable image contrast, while presenting significantly higher SNR than the fully sampled images (p<.01) at 2-, 3- and 4-X acceleration. In quantitative measurements, renal perfusion results were in good agreement with the fully sampled one (concordance correlation coefficient=0.95, 0.91, 0.88) at 2-, 3- and 4-X acceleration in CS simulation. Moreover, in realistic acquisitions, the estimated perfusion by the separable compartmental model exhibited no significant differences (p>.05) between each CS-accelerated acquisition and the full sampling method.
Conclusion: The CS-combined 3D sequence could improve the temporal resolution for DCE-MRI in kidney while yielding diagnostically acceptable image quality, and it could provide effective measurements of renal perfusion.
Keywords: Compressed sensing; DCE-MRI; Kidney; Perfusion; Temporal resolution.
Copyright © 2015 Elsevier Inc. All rights reserved.
Similar articles
-
Quantification of renal perfusion: comparison of arterial spin labeling and dynamic contrast-enhanced MRI.J Magn Reson Imaging. 2011 Sep;34(3):608-15. doi: 10.1002/jmri.22660. Epub 2011 Jul 14. J Magn Reson Imaging. 2011. PMID: 21761490
-
Temporal resolution improvement of calibration-free dynamic contrast-enhanced MRI with compressed sensing optimized turbo spin echo: The effects of replacing turbo factor with compressed sensing accelerations.J Magn Reson Imaging. 2016 Jul;44(1):138-47. doi: 10.1002/jmri.25136. Epub 2015 Dec 29. J Magn Reson Imaging. 2016. PMID: 26713414
-
Absolute quantification of regional renal blood flow in swine by dynamic contrast-enhanced magnetic resonance imaging using a blood pool contrast agent.Invest Radiol. 2009 Mar;44(3):125-34. doi: 10.1097/RLI.0b013e318193598c. Invest Radiol. 2009. PMID: 19151609
-
[Quantitative perfusion imaging in magnetic resonance imaging].Radiologe. 2016 Feb;56(2):113-23. doi: 10.1007/s00117-015-0068-4. Radiologe. 2016. PMID: 26796337 Review. German.
-
Compressed sensing MRI: a review of the clinical literature.Br J Radiol. 2015;88(1056):20150487. doi: 10.1259/bjr.20150487. Epub 2015 Sep 24. Br J Radiol. 2015. PMID: 26402216 Free PMC article. Review.
Cited by
-
Sparse Reconstruction Techniques in Magnetic Resonance Imaging: Methods, Applications, and Challenges to Clinical Adoption.Invest Radiol. 2016 Jun;51(6):349-64. doi: 10.1097/RLI.0000000000000274. Invest Radiol. 2016. PMID: 27003227 Free PMC article. Review.
-
Multiresolution imaging using golden angle stack-of-stars and compressed sensing for dynamic MR urography.J Magn Reson Imaging. 2017 Jul;46(1):303-311. doi: 10.1002/jmri.25576. Epub 2017 Feb 8. J Magn Reson Imaging. 2017. PMID: 28176396 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources