Combined use of hyperbaric and hypobaric ropivacaine significantly improves hemodynamic characteristics in spinal anesthesia for caesarean section: a prospective, double-blind, randomized, controlled study
- PMID: 25970485
- PMCID: PMC4430289
- DOI: 10.1371/journal.pone.0125014
Combined use of hyperbaric and hypobaric ropivacaine significantly improves hemodynamic characteristics in spinal anesthesia for caesarean section: a prospective, double-blind, randomized, controlled study
Erratum in
-
Correction: Combined Use of Hyperbaric and Hypobaric Ropivacaine Significantly Improves Hemodynamic Characteristics in Spinal Anesthesia for Caesarean Section: A Prospective, Double-Blind, Randomized, Controlled Study.PLoS One. 2015 Jun 25;10(6):e0132082. doi: 10.1371/journal.pone.0132082. eCollection 2015. PLoS One. 2015. PMID: 26111039 Free PMC article. No abstract available.
Abstract
Purpose: To observe the hemodynamic changes of parturients in the combined use of hyperbaric (4 mg) and hypobaric (6 mg) ropivacaine during spinal anesthesia for caesarean section in this randomized double-blind study.
Methods: Parturients (n = 136) undergoing elective cesarean delivery were randomly and equally allocated to receive either combined hyperbaric and hypobaric ropivacaine (Group A) or hyperbaric ropivacaine (Group B). Outcome measures were: hemodynamic characteristics, maximum height of sensory block, time to achieve T8 sensory blockade level, incidence of complications, Apgar scores at 1 and 5 min, and neonatal blood gas analysis.
Results: Group A had a lower level of sensory blockade (T6 [T6-T7]) and longer time to achieve T8 sensory blockade level (8 ± 1.3 min) than did patients in Group B (T3 [T2-T4] and 5 ± 1.0 min, respectively; P < 0.001, both). The incidence rates for hypotension, nausea, and vomiting were significantly lower in Group A (13%, 10%, and 3%, respectively) than Group B (66%, 31%, and 13%; P < 0.001, P = 0.003, P = 0.028).
Conclusions: Combined use of hyperbaric (4 mg) and hypobaric (6 mg) ropivacaine significantly decreased the incidences of hypotension and complications in spinal anesthesia for caesarean section by extending induction time and decreasing the level of sensory blockade.
Trial registration: Chinese Clinical Trial Register ChiCTR-TRC-13004622.
Conflict of interest statement
Figures
References
Publication types
MeSH terms
Substances
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical