Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings
- PMID: 25972188
- PMCID: PMC4432962
- DOI: 10.1186/s12985-015-0306-4
Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings
Abstract
Background: Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results.
Methods: Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result.
Results: 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %.
Conclusion: This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false negative results due to seroconversion or misclassification by the lower sensitivity dilution test. Further research is needed to determine if these results can be replicated in other settings.
Trial registration: ClinicalTrials.gov, NCT01716299 .
Similar articles
-
Evaluation of HIV testing algorithms in Ethiopia: the role of the tie-breaker algorithm and weakly reacting test lines in contributing to a high rate of false positive HIV diagnoses.BMC Infect Dis. 2015 Feb 3;15:39. doi: 10.1186/s12879-015-0769-3. BMC Infect Dis. 2015. PMID: 25645240 Free PMC article.
-
Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?PLoS One. 2015 Jul 10;10(7):e0132422. doi: 10.1371/journal.pone.0132422. eCollection 2015. PLoS One. 2015. PMID: 26161864 Free PMC article.
-
Self-reported HIV-positive status but subsequent HIV-negative test result using rapid diagnostic testing algorithms among seven sub-Saharan African military populations.PLoS One. 2017 Jul 7;12(7):e0180796. doi: 10.1371/journal.pone.0180796. eCollection 2017. PLoS One. 2017. PMID: 28686678 Free PMC article.
-
HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites.J Int AIDS Soc. 2017 Jul 3;20(1):21419. doi: 10.7448/IAS.20.1.21419. J Int AIDS Soc. 2017. PMID: 28691437 Free PMC article. Review.
-
Causes of false-positive HIV rapid diagnostic test results.Expert Rev Anti Infect Ther. 2014 Jan;12(1):49-62. doi: 10.1586/14787210.2014.866516. Expert Rev Anti Infect Ther. 2014. PMID: 24404993 Review.
Cited by
-
Performance evaluation of the Asante Rapid Recency Assay for verification of HIV diagnosis and detection of recent HIV-1 infections: Implications for epidemic control.PLOS Glob Public Health. 2022 May 3;2(5):e0000316. doi: 10.1371/journal.pgph.0000316. eCollection 2022. PLOS Glob Public Health. 2022. PMID: 36962217 Free PMC article.
-
Development of an approach to monitor the manufacturing consistency of HIV rapid diagnostic tests: Panel qualification and potential impact on country programs.PLoS One. 2023 Apr 10;18(4):e0284175. doi: 10.1371/journal.pone.0284175. eCollection 2023. PLoS One. 2023. PMID: 37036848 Free PMC article.
-
False-positive HIV diagnoses: lessons from Ugandan and Russian research cohorts.HIV Clin Trials. 2018 Feb;19(1):15-22. doi: 10.1080/15284336.2018.1429846. Epub 2018 Jan 31. HIV Clin Trials. 2018. PMID: 29384717 Free PMC article.
-
High positive HIV serology results can still be false positive.IDCases. 2020 May 28;21:e00849. doi: 10.1016/j.idcr.2020.e00849. eCollection 2020. IDCases. 2020. PMID: 32514397 Free PMC article.
References
-
- World Health Organization . Service delivery approaches to HIV testing and Counselling (HTC) Geneva: WHO; 2012.
-
- Gray RH, Makumbi F, Serwadda D, Lutalo T, Nalugoda F, Opendi P, et al. Limitations of rapid HIV-1 tests during screening for trials in Uganda: diagnostic test accuracy study. BMJ. 2007;335(7612):188. doi: 10.1136/bmj.39210.582801.BE. - DOI - PMC - PubMed
-
- Aghokeng AF, Mpoudi-Ngole E, Dimodi H, Atem-Tambe A, Tongo M, Butel C, et al. Inaccurate diagnosis of HIV-1 Group M and O is a key challenge for ongoing universal access to antiretroviral treatment and HIV prevention in Cameroon. PLoS One. 2009;4(11) doi: 10.1371/journal.pone.0007702. - DOI - PMC - PubMed
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical