The technological future of 7 T MRI hardware
- PMID: 25974894
- DOI: 10.1002/nbm.3315
The technological future of 7 T MRI hardware
Abstract
In this article we present our projections of future hardware developments on 7 T human MRI systems. These include compact cryogen-light magnets, improved gradient performance, integrated RF-receive and direct current shimming coil arrays, new RF technology with adaptive impedance matching, patient-specific specific absorption rate estimation and monitoring, and increased integration of physiological monitoring systems. Copyright © 2015 John Wiley & Sons, Ltd.
Keywords: Johan Cruyff; RF coils; active impedance matching; high field MRI; high order shimming; magnetic field gradients; physiological monitoring; superconducting magnets.
Copyright © 2015 John Wiley & Sons, Ltd.
Similar articles
-
Concurrent recording of RF pulses and gradient fields - comprehensive field monitoring for MRI.NMR Biomed. 2016 Sep;29(9):1162-72. doi: 10.1002/nbm.3359. Epub 2015 Aug 13. NMR Biomed. 2016. PMID: 26269210
-
(1) H MRS in the human spinal cord at 7 T using a dielectric waveguide transmitter, RF shimming and a high density receive array.NMR Biomed. 2016 Sep;29(9):1231-9. doi: 10.1002/nbm.3541. Epub 2016 May 18. NMR Biomed. 2016. PMID: 27191947
-
Magnetic field shimming of a permanent magnet using a combination of pieces of permanent magnets and a single-channel shim coil for skeletal age assessment of children.J Magn Reson. 2013 May;230:125-33. doi: 10.1016/j.jmr.2013.02.005. Epub 2013 Feb 14. J Magn Reson. 2013. PMID: 23475056
-
W(h)ither human cardiac and body magnetic resonance at ultrahigh fields? technical advances, practical considerations, applications, and clinical opportunities.NMR Biomed. 2016 Sep;29(9):1173-97. doi: 10.1002/nbm.3268. Epub 2015 Feb 23. NMR Biomed. 2016. PMID: 25706103 Review.
-
Autocalibrated coil sensitivity estimation for parallel imaging.NMR Biomed. 2006 May;19(3):316-24. doi: 10.1002/nbm.1048. NMR Biomed. 2006. PMID: 16705632 Review.
Cited by
-
Open Source 3D Multipurpose Measurement System with Submillimetre Fidelity and First Application in Magnetic Resonance.Sci Rep. 2017 Oct 18;7(1):13452. doi: 10.1038/s41598-017-13824-z. Sci Rep. 2017. PMID: 29044156 Free PMC article.
-
Spinal cord MRI at 7T.Neuroimage. 2018 Mar;168:437-451. doi: 10.1016/j.neuroimage.2017.07.003. Epub 2017 Jul 3. Neuroimage. 2018. PMID: 28684332 Free PMC article. Review.
-
From ultrahigh to extreme field magnetic resonance: where physics, biology and medicine meet.MAGMA. 2016 Jun;29(3):309-11. doi: 10.1007/s10334-016-0564-1. MAGMA. 2016. PMID: 27221262 No abstract available.
-
Ultra-high-field 7T MRI in Parkinson's disease: ready for clinical use?-a narrative review.Quant Imaging Med Surg. 2023 Nov 1;13(11):7607-7620. doi: 10.21037/qims-23-509. Epub 2023 Oct 17. Quant Imaging Med Surg. 2023. PMID: 37969629 Free PMC article. Review.
-
Integrated parallel reception, excitation, and shimming (iPRES) with multiple shim loops per radio-frequency coil element for improved B0 shimming.Magn Reson Med. 2017 May;77(5):2077-2086. doi: 10.1002/mrm.26267. Epub 2016 May 13. Magn Reson Med. 2017. PMID: 27174387 Free PMC article.