Patient specific stress and rupture analysis of ascending thoracic aneurysms
- PMID: 25979384
- DOI: 10.1016/j.jbiomech.2015.04.035
Patient specific stress and rupture analysis of ascending thoracic aneurysms
Abstract
An ascending thoracic aortic aneurysm (ATAA) is a serious medical condition which, more often than not, requires surgery. Aneurysm diameter is the primary clinical criterion for determining when surgical intervention is necessary but, biomechanical studies have suggested that the diameter criterion is insufficient. This manuscript presents a method for obtaining the patient specific wall stress distribution of the ATAA and the retrospective rupture risk for each patient. Five human ATAAs and the preoperative dynamic CT scans were obtained during elective surgeries to replace each patient's aneurysm with a synthetic graft. The material properties and rupture stress for each tissue sample were identified using bulge inflation tests. The dynamic CT scans were used to generate patient specific geometries for a finite element (FE) model of each patient's aneurysm. The material properties from the bulge inflation tests were implemented in the FE model and the wall stress distribution at four different pressures was estimated. Three different rupture risk assessments were compared: the maximum diameter, the rupture risk index, and the overpressure index. The peak wall stress values for the patients ranged from 28% to 94% of the ATAA's failure stress. The rupture risk and overpressure indices were both only weakly correlated with diameter (ρ=-0.29, both cases). In the future, we plan to conduct a large experimental and computational study that includes asymptomatic patients under surveillance, patients undergoing elective surgery, and patients who have experienced rupture or dissection to determine if the rupture risk index or maximum diameter can meaningfully differentiate between the groups.
Keywords: Aneurysm rupture; Ascending thoracic aortic aneurysm; Finite element analysis; Patient specific material properties; Rupture risk; Wall stress.
Copyright © 2015 Elsevier Ltd. All rights reserved.
Similar articles
-
Wall stress analyses in patients with ≥5 cm versus <5 cm ascending thoracic aortic aneurysm.J Thorac Cardiovasc Surg. 2021 Nov;162(5):1452-1459. doi: 10.1016/j.jtcvs.2020.02.046. Epub 2020 Feb 19. J Thorac Cardiovasc Surg. 2021. PMID: 32178922 Free PMC article.
-
Ascending thoracic aortic aneurysm wall stress analysis using patient-specific finite element modeling of in vivo magnetic resonance imaging.Interact Cardiovasc Thorac Surg. 2015 Oct;21(4):471-80. doi: 10.1093/icvts/ivv186. Epub 2015 Jul 14. Interact Cardiovasc Thorac Surg. 2015. PMID: 26180089 Free PMC article.
-
Patient-specific finite element analysis of ascending thoracic aortic aneurysm.J Heart Valve Dis. 2014 Nov;23(6):765-72. J Heart Valve Dis. 2014. PMID: 25790625 Free PMC article.
-
Biomechanics of the Ascending Thoracic Aorta: A Clinical Perspective on Engineering Data.Can J Cardiol. 2016 Jan;32(1):35-47. doi: 10.1016/j.cjca.2015.10.015. Epub 2015 Oct 23. Can J Cardiol. 2016. PMID: 26724509 Review.
-
Biomechanical Indices for Rupture Risk Estimation in Abdominal Aortic Aneurysms.J Endovasc Ther. 2017 Apr;24(2):254-261. doi: 10.1177/1526602816680088. Epub 2016 Nov 21. J Endovasc Ther. 2017. PMID: 27872318 Review.
Cited by
-
Biomechanics of aortic wall failure with a focus on dissection and aneurysm: A review.Acta Biomater. 2019 Nov;99:1-17. doi: 10.1016/j.actbio.2019.08.017. Epub 2019 Aug 13. Acta Biomater. 2019. PMID: 31419563 Free PMC article. Review.
-
Failure of the Porcine Ascending Aorta: Multidirectional Experiments and a Unifying Microstructural Model.J Biomech Eng. 2017 Mar 1;139(3):0310051-03100514. doi: 10.1115/1.4035264. J Biomech Eng. 2017. PMID: 27893044 Free PMC article.
-
Multimodality Imaging-Based Characterization of Regional Material Properties in a Murine Model of Aortic Dissection.Sci Rep. 2020 Jun 8;10(1):9244. doi: 10.1038/s41598-020-65624-7. Sci Rep. 2020. PMID: 32514185 Free PMC article.
-
The Influence of Material Properties and Wall Thickness on Predicted Wall Stress in Ascending Aortic Aneurysms: A Finite Element Study.Cardiovasc Eng Technol. 2025 Feb;16(1):52-65. doi: 10.1007/s13239-024-00756-9. Epub 2024 Oct 25. Cardiovasc Eng Technol. 2025. PMID: 39455477 Free PMC article.
-
Estimating nonlinear anisotropic properties of healthy and aneurysm ascending aortas using magnetic resonance imaging.Biomech Model Mechanobiol. 2025 Feb;24(1):233-250. doi: 10.1007/s10237-024-01907-6. Epub 2024 Nov 26. Biomech Model Mechanobiol. 2025. PMID: 39586942 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources