Abstract
Background: Stable trochanteric femur fractures can be treated successfully with conventional implants such as sliding hip screw, cephalomedullary nails, angular blade plates. However comminuted and unstable inter or subtrochanteric fractures with or without osteoporosis are challenging & prone to complications. The PF-LCP is a new implant that allows angular stability by creating fixed angle block for treatment of complex, comminuted proximal femoral fractures.
Method: We reviewed 30 patients with unstable inter or subtrochanteric fractures, which were stabilized with PF-LCP. Mean age of patient was 65 years, and average operative time was 80 min. Patients were followed up for a period of 3 years (June 2010-June 2013). Patients were examined regularly at 3 weekly interval for signs of union (radiological & clinical), varus collapse (neck-shaft angle), limb shortening, and hardware failure.
Result: All patients showed signs of union at an average of 9 weeks (8-10 weeks), with minimum varus collapse (<10°), & no limb shortening and hardware failure. Results were analysed using IOWA (Larson) hip scoring. Average IOWA hip score was 77.5.
Conclusion: PF-LCP represents a feasible alternative for treatment of unstable inter- or subtrochanteric fractures.
Keywords: Angular stability; Osteoporosis; PF-LCP; Proximal femur; Unstable.
Figures

















Similar articles
-
Evaluation of outcome of proximal femur locking compression plate (PFLCP) in unstable proximal femur fractures.J Clin Orthop Trauma. 2017 Oct-Dec;8(4):308-312. doi: 10.1016/j.jcot.2016.11.005. Epub 2016 Nov 21. J Clin Orthop Trauma. 2017. PMID: 29062210 Free PMC article.
-
Biological fixation of comminuted subtrochanteric fractures with proximal femur locking compression plate.Injury. 2013 Feb;44(2):226-31. doi: 10.1016/j.injury.2012.10.037. Epub 2012 Nov 30. Injury. 2013. PMID: 23200761
-
Functional and Radiological Outcomes of Unstable Proximal Femur Fractures Fixed With Anatomical Proximal Locking Compression Plate.Cureus. 2022 May 11;14(5):e24903. doi: 10.7759/cureus.24903. eCollection 2022 May. Cureus. 2022. PMID: 35719830 Free PMC article.
-
Results of Subtrochanteric Femoral Fractures Fixation by Proximal Femoral Locking Compression Plate.Mymensingh Med J. 2024 Oct;33(4):1016-1025. Mymensingh Med J. 2024. PMID: 39351719
-
Alternative techniques in trochanteric hip fracture surgery. Clinical and biomechanical studies on the Medoff sliding plate and the Twin hook.Acta Orthop Scand Suppl. 2000 Oct;295:1-31. Acta Orthop Scand Suppl. 2000. PMID: 11116961 Review.
Cited by
-
Locking plate and fibular strut-graft augmentation in the reconstruction of unicameral bone cyst of proximal femur in the paediatric population.Int Orthop. 2018 Jan;42(1):169-174. doi: 10.1007/s00264-017-3648-2. Epub 2017 Sep 30. Int Orthop. 2018. PMID: 28963665
-
Comparing the Intramedullary Nailing Method Versus Dynamic Hip Screw in Treatment of Unstable Intertrochanteric Fractures.Med Arch. 2016 Feb;70(1):53-6. doi: 10.5455/medarh.2016.70.53-56. Epub 2016 Jan 31. Med Arch. 2016. PMID: 26980933 Free PMC article.
-
Management of unstable pertrochanteric fractures, evaluation of forgotten treatment options.SICOT J. 2020;6:21. doi: 10.1051/sicotj/2020020. Epub 2020 Jun 24. SICOT J. 2020. PMID: 32579105 Free PMC article.
-
Management of unstable pertrochanteric fractures with proximal femoral locking compression plates and affect of neck-shaft angle on functional outcomes.J Clin Orthop Trauma. 2017 Jul-Sep;8(3):209-214. doi: 10.1016/j.jcot.2017.07.006. Epub 2017 Jul 15. J Clin Orthop Trauma. 2017. PMID: 28951636 Free PMC article.
-
A biomechanical comparison of three fixation techniques in osteoporotic reverse oblique intertrochanteric femur fracture with fragmented lateral cortex.Eur J Trauma Emerg Surg. 2019 Jun;45(3):499-505. doi: 10.1007/s00068-018-1061-1. Epub 2019 Jan 2. Eur J Trauma Emerg Surg. 2019. PMID: 30600335
References
-
- Ehmke L.W., Fitzpatrick D.C., Krieg J.C. Lag screws for hip fracture fixation: evaluation of migration resistance under simulated walking. J Orthop Res. 2005;23:1329–1335. - PubMed
-
- Dobbs R.E., Parvizi J., Lewallen D.G. Perioperative morbidity and 30-day mortality after intertrochanteric hip fractures treated by internal fixation or arthroplasty. J Arthroplasty. 2005;20(8):963–966. - PubMed
-
- Rockwood and green’s fractures in adults, vol. 2, 7th ed. Intertrochanteric Fractures. Thomas A Russell. Page 1597–1600.
-
- Koot V.C.M., Kesselaer S.M.M.J., Clevers G.J., DeHooge P., Weits T. Evaluation of the singh index for measuring osteoporosis. J Bone Joint Surg [Br] 1996;78-B:831–838. - PubMed
-
- Hasenboehler Erik A., Agudelo Juan F., Morgan Steven J., Smith Wade R., Hak David J., Stahel Philip F. Treatment of complex proximal femoral fractures with proximal femur locking compression plate. Orthopaedics. August 2007;30(8) - PubMed
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical