Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2015 Jun;6(2):108-12.
doi: 10.1016/j.jcot.2015.01.096. Epub 2015 Feb 19.

Polyethylene in knee arthroplasty: A review

Affiliations
Review

Polyethylene in knee arthroplasty: A review

Gautam Chakrabarty et al. J Clin Orthop Trauma. 2015 Jun.

Abstract

Polyethylene (PE) has been used extensively in knee arthroplasty since the mid 20th century. Progress in material manufacturing and processing has led to newer polyethylenes over last few decades with different material properties. It has been established that PE wear in knee arthroplasty causes particle induced osteolysis which is the main reason for late failure and requires revision surgery. Although there are various causes of wear, the properties of PE have long been a matter of investigation as a contributory factor. The advent of newer highly cross linked PE has been shown to improve wear rates in hip arthroplasty but the benefits have not been shown to be of the same degree in knee arthroplasty. The laboratory and clinical studies so far are limited and slightly conflicting in their conclusions. The risks of using highly cross linked PE in knee arthroplasty include tibial post fracture, disruption of locking mechanism, liner fracture which can lead to increased wear and osteolysis. The current evidence suggests that highly cross linked polyethylenes should be used with caution and only considered in younger active patients. The results of a recently completed randomized trial to compare the conventional with high molecular weight PE in knee arthroplasty are awaited.

Keywords: Highly cross linked; Polyethylene; Total knee replacement.

PubMed Disclaimer

References

    1. Piringer Otto G., Baner Albert Lawrence. 2nd ed. Wiley-VCH; 2008. Plastic Packaging: Interactions with Food and Pharmaceuticals.
    1. Pechmann H.V. Ueber Diazomethan. Berichte Dtsch Chem Ges. 1894;27:1888–1891.
    1. Trossarelli L., Brunella V. UHMWPE Meeting, Held on 19 September 2003. University of Torino; Italy: 2003. Polyethylene, discovery and growth.
    1. Malpass Dennis B. Wiley-VCH; 2010. Introduction to Industrial Polyethylene: Properties, Catalysts, and Processes.
    1. Naudie D.D.R., Ammeen D.J., Engh G.A., Rorabeck C. Wear an osteolysis around total knee arthroplasty. J Am Acad Orthop Surg. 2007 Jan;15:53–64. - PubMed

LinkOut - more resources