Multicenter Study
. 2015 Oct;56(5):787-91.
Epub 2015 May 21.

Physician-initiated prospective Italian Registry of carotid stenting with the C-Guard mesh-stent: the IRON-Guard registry. Rationale and design

Collaborators, Affiliations
  • PMID: 25996843
Multicenter Study

Physician-initiated prospective Italian Registry of carotid stenting with the C-Guard mesh-stent: the IRON-Guard registry. Rationale and design

C Setacci et al. J Cardiovasc Surg (Torino). 2015 Oct.

Abstract

According to the World Health Organization, every year, 5 million peoples die for stroke and another 5 million are permanently disabled. Although there are many causes of acute stroke, a common treatable cause of acute stroke is atheromatous narrowing at the carotid bifurcation. Carotid endarterectomy is still the standard of car, even if carotid artery stenting (CAS) has become an effective, less invasive alterantive. Unfortunately, CAS procedure is not yet perfect; regardless the use of an embolic protection device (EPD), percutaneous treatment has been correlated with a risk of cerebral ischemic events related to distal embolization. The objective of the IRON-Guard Registry is to evaluate the clinical outcome of treatment by means of stenting with the C-Guard (InspireMD, Boston, MA, USA) in subjects requiring CAS due to significant extracranial carotid artery stenosis with a physician-initiated, Italian, prospective, multicenter, single-arm study. A total of 200 enrolled subjects divided over different centers are planned to be enrolled. CAS will performed by implanting of C-Guard stent. Procedure will be performed according to the physician's standard of care. Standard procedures will be followed based on the Instructions for Use, for the C-Guard device of Inspire. The primary endpoint of this study is the 30-day rate of major adverse events (MAE), defined as the cumulative incidence of any periprocedural (≤30 days postprocedure) death, stroke or myocardial infarction. Secondary endpoints are rate of late ipsilateral stroke (31 through 365 days), system technical success, device malfunctions, major adverse events (MAEs), serious device-related and procedure-related adverse events, target lesion revascularization, and in-stent restenosis rates.