Pulmonary transvascular flux of transferrin
- PMID: 2600018
- DOI: 10.1152/jappl.1989.67.5.1850
Pulmonary transvascular flux of transferrin
Abstract
We compared the pulmonary transvascular fluxes of transferrin and albumin in the intact sheep lung. Anesthetized sheep were prepared with lung lymph fistulas. The vascular blood pool was marked with 99mTc-erythrocytes, autologous transferrin was labeled with 113mIn, and albumin was labeled with 125I. Samples of blood, plasma, lymph, and lung were obtained up to 180 min after tracer infusion. Lymph tissue radioactivities were corrected for the intravascular component and expressed as extravascular-to-plasma concentration ratios. Clearance of transferrin and albumin from the plasma space followed a two-compartment model. The clearance rate constant was 2.1 +/- 0.1 x 10(-3) min for albumin and 2.4 +/- 0.1 x 10(-3) min for transferrin (P less than 0.05). Lymph-to-plasma ratios for albumin and transferrin were not different. However, the extravascular-to-plasma ratio for albumin was greater than transferrin (P less than 0.05). The lymph and lung data were deconvoluted for the plasma input function and fit to a two-compartment model. The results indicate that albumin and transferrin have similar permeabilities across the vascular barrier but have different pulmonary circulation to lymph kinetics because the extravascular volume of distribution of albumin is greater than transferrin.
Similar articles
-
Evaluating flux of labeled albumin into the pulmonary interstitium of sheep lungs.J Appl Physiol (1985). 1992 Jan;72(1):29-38. doi: 10.1152/jappl.1992.72.1.29. J Appl Physiol (1985). 1992. PMID: 1537728
-
Lung fluid dynamics in awake newborn lambs.J Clin Invest. 1977 Nov;60(5):1107-15. doi: 10.1172/JCI108862. J Clin Invest. 1977. PMID: 908754 Free PMC article.
-
Transvascular albumin and IgG flux in skin and skeletal muscle following plasmapheresis.Microvasc Res. 1992 Nov;44(3):295-306. doi: 10.1016/0026-2862(92)90089-8. Microvasc Res. 1992. PMID: 1479930
-
The evaluation of lung function with PET.Semin Nucl Med. 1998 Oct;28(4):341-51. doi: 10.1016/s0001-2998(98)80037-8. Semin Nucl Med. 1998. PMID: 9800239 Review.
-
Distribution of transvascular pathway sizes through the pulmonary microvascular barrier.Ann Biomed Eng. 1987;15(2):139-55. doi: 10.1007/BF02364050. Ann Biomed Eng. 1987. PMID: 3296872 Review.
Cited by
-
Radionuclide assessment of pulmonary microvascular permeability.Eur J Nucl Med. 1997 Apr;24(4):449-61. doi: 10.1007/BF00881821. Eur J Nucl Med. 1997. PMID: 9096099 Review.
-
Measurement of protein flux with positron emission tomography in neonates.Arch Dis Child Fetal Neonatal Ed. 1999 Jan;80(1):F26-9. doi: 10.1136/fn.80.1.f26. Arch Dis Child Fetal Neonatal Ed. 1999. PMID: 10325807 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources