Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 May 22;10(5):e0127914.
doi: 10.1371/journal.pone.0127914. eCollection 2015.

Suitability of UK Biobank Retinal Images for Automatic Analysis of Morphometric Properties of the Vasculature

Collaborators, Affiliations

Suitability of UK Biobank Retinal Images for Automatic Analysis of Morphometric Properties of the Vasculature

Thomas J MacGillivray et al. PLoS One. .

Abstract

Purpose: To assess the suitability of retinal images held in the UK Biobank--the largest retinal data repository in a prospective population-based cohort--for computer assisted vascular morphometry, generating measures that are commonly investigated as candidate biomarkers of systemic disease.

Methods: Non-mydriatic fundus images from both eyes of 2,690 participants--people with a self-reported history of myocardial infarction (n=1,345) and a matched control group (n=1,345)--were analysed using VAMPIRE software. These images were drawn from those of 68,554 UK Biobank participants who underwent retinal imaging at recruitment. Four operators were trained in the use of the software to measure retinal vascular tortuosity and bifurcation geometry.

Results: Total operator time was approximately 360 hours (4 minutes per image). 2,252 (84%) of participants had at least one image of sufficient quality for the software to process, i.e. there was sufficient detection of retinal vessels in the image by the software to attempt the measurement of the target parameters. 1,604 (60%) of participants had an image of at least one eye that was adequately analysed by the software, i.e. the measurement protocol was successfully completed. Increasing age was associated with a reduced proportion of images that could be processed (p=0.0004) and analysed (p<0.0001). Cases exhibited more acute arteriolar branching angles (p=0.02) as well as lower arteriolar and venular tortuosity (p<0.0001).

Conclusions: A proportion of the retinal images in UK Biobank are of insufficient quality for automated analysis. However, the large size of the UK Biobank means that tens of thousands of images are available and suitable for computational analysis. Parametric information measured from the retinas of participants with suspected cardiovascular disease was significantly different to that measured from a matched control group.

PubMed Disclaimer

Conflict of interest statement

Competing Interests: The authors have declared that no competing interests exist.

References

    1. Department of Health, UK Government. Long Term Conditions Compendium of Information (Third Edition); 2012. [updated on 30 May 2012; cited on 7 November 2013]. Available from: https://www.gov.uk/
    1. The Scottish Government. Long term Conditions; 2013 [updated on 22 November 2013; cited on 27 November 2013]. Available from: http://www.scotland.gov.uk/Topics/Health/Services/Long-Term-Conditions
    1. Department of Health, Social Services and Public Safety, Northern Ireland Government. Living with Long Term Conditions; April 2012 [cited on 22 November 2013]. Available from: http://www.dhsspsni.gov.uk/long-term-condition.htm
    1. Centers for Disease Control and Prevention. Chronic Diseases and Health Promotion; 2013 [updated on 13 August 2012; cited on 9 December 2013]. Available from: http://www.cdc.gov/chronicdisease/overview/index.htm
    1. Liew G, Wang JJ. Retinal Vascular Signs: A Window to the Heart? Revista Española de Cardiología (English Edition). 2011;64(6):515–521. - PubMed

Publication types