Measuring Infant Visual Acuity with Gaze Tracker Monitored Visual Fixation
- PMID: 26002001
- DOI: 10.1097/OPX.0000000000000613
Measuring Infant Visual Acuity with Gaze Tracker Monitored Visual Fixation
Abstract
Purpose: To validate a method of measuring grating acuity with remote gaze tracking (GT) against a current clinical test of visual acuity (VA), the Teller Acuity Cards (TACs), as part of the development of an automated VA test for infants.
Methods: Visual acuity for computer-generated horizontal square-wave gratings was determined from relative fixation time on a grating area compared with the background. In experiment 1, binocular VA was based on eye movements with a GT in 15 uncorrected myopic adults and compared with VA measured with subjective responses with the same stimuli and with the TACs. In experiment 2, binocular VA was determined in 19 typically developing infants aged 3 to 11 months on two visits with both the GT and TACs.
Results: In adults, the mean difference between VA measured by the GT and TACs was 0.01 log cycles per degree (cpd) and the 95% limits of agreement were 0.11. One hundred percent of GT VA results were within 0.5 octave of the TACs' VAs. The mean difference between the GT and TACs for infants was 0.17 log cpd on both the first and second visit (95% limits of agreement, 0.42 and 0.47, respectively). The mean difference between test and retest for infant GT VA was 0.06 log cpd, and limits of agreement for repeatability were 0.48 log cpd. In infants, both the TACs and the GT had a reliability of 89% within less than or equal to 1 octave between visits. Gaze tracking VA improved with age and is in agreement with published norms.
Conclusions: The agreement between the TACs and GT in adults and infants validates the method of measuring grating acuity with the remote GT. These results demonstrate its potential for an automated test of infant VA.
Similar articles
-
Automated assessment of grating acuity in infants and toddlers using an eye-tracking system.J Vis. 2022 Nov 1;22(12):8. doi: 10.1167/jov.22.12.8. J Vis. 2022. PMID: 36331256 Free PMC article.
-
Automated measurement of resolution acuity in infants using remote eye-tracking.Invest Ophthalmol Vis Sci. 2014 Oct 28;55(12):8102-10. doi: 10.1167/iovs.14-15108. Invest Ophthalmol Vis Sci. 2014. PMID: 25352118
-
Similarities and differences between behavioral and electrophysiological visual acuity thresholds in healthy infants during the second half of the first year of life.Doc Ophthalmol. 2017 Apr;134(2):99-110. doi: 10.1007/s10633-017-9576-z. Epub 2017 Feb 20. Doc Ophthalmol. 2017. PMID: 28220265
-
Behavioral tests of visual acuity in infants.Int Ophthalmol Clin. 1980 Spring;20(1):233-50. doi: 10.1097/00004397-198002010-00011. Int Ophthalmol Clin. 1980. PMID: 6995377 Review.
-
Grating acuity tests for infants, young children and individuals with disabilities: A review of recent advances.Semin Ophthalmol. 2023 Jan;38(1):76-84. doi: 10.1080/08820538.2022.2116987. Epub 2022 Sep 8. Semin Ophthalmol. 2023. PMID: 36073743 Review.
Cited by
-
Saccade latencies during a preferential looking task and objective scoring of grating acuity in children with and without visual impairments.Acta Ophthalmol. 2019 Sep;97(6):616-625. doi: 10.1111/aos.14011. Epub 2019 Feb 7. Acta Ophthalmol. 2019. PMID: 30734501 Free PMC article.
-
A review of experimental task design in psychophysical eye tracking research.Front Hum Neurosci. 2023 Aug 17;17:1112769. doi: 10.3389/fnhum.2023.1112769. eCollection 2023. Front Hum Neurosci. 2023. PMID: 37662635 Free PMC article. Review.
-
Automated assessment of grating acuity in infants and toddlers using an eye-tracking system.J Vis. 2022 Nov 1;22(12):8. doi: 10.1167/jov.22.12.8. J Vis. 2022. PMID: 36331256 Free PMC article.
-
Development of Automated Visual Acuity Measurement Using a Calibration-Free Eye-Tracking System.Cureus. 2024 Jul 12;16(7):e64401. doi: 10.7759/cureus.64401. eCollection 2024 Jul. Cureus. 2024. PMID: 39130869 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous