Quantification of material slippage in the iliotibial tract when applying the partial plastination clamping technique
- PMID: 26005842
- DOI: 10.1016/j.jmbbm.2015.04.028
Quantification of material slippage in the iliotibial tract when applying the partial plastination clamping technique
Abstract
The objective of this study was to evaluate the potential of the partial plastination technique in minimizing material slippage and to discuss the effects on the tensile properties of thin dense connective tissue. The ends of twelve iliotibial tract samples were primed with polyurethane resin and covered by plastic plates to provide sufficient grip between the clamps. The central part of the samples remained in an anatomically unfixed condition. Strain data of twelve partially plastinated samples and ten samples in a completely anatomically unfixed state were obtained using uniaxial crosshead displacement and an optical image tracking technique. Testing of agreement between the strain data revealed ongoing but markedly reduced material slippage in partially plastinated samples compared to the unfixed samples. The mean measurement error introduced by material slippage was up to 18.0% in partially plastinated samples. These findings might complement existing data on measurement errors during material testing and highlight the importance of individual quantitative evaluation of errors that come along with self-made clamping techniques.
Keywords: Clamping; Connective tissue; Digital image correlation technique; Material slippage; Partial plastination technique; Strain.
Copyright © 2015 Elsevier Ltd. All rights reserved.
Similar articles
-
Deformation behavior of the iliotibial tract under different states of fixation.Med Eng Phys. 2012 Nov;34(9):1221-7. doi: 10.1016/j.medengphy.2011.12.009. Epub 2012 Jan 31. Med Eng Phys. 2012. PMID: 22297087
-
Surface coating and speckling of the human iliotibial tract does not affect its load-deformation properties.Sci Rep. 2020 Nov 27;10(1):20747. doi: 10.1038/s41598-020-77299-1. Sci Rep. 2020. PMID: 33247150 Free PMC article.
-
Uniaxial and biaxial mechanical properties of porcine linea alba.J Mech Behav Biomed Mater. 2015 Jan;41:68-82. doi: 10.1016/j.jmbbm.2014.09.026. Epub 2014 Oct 7. J Mech Behav Biomed Mater. 2015. PMID: 25460404
-
Extracting accurate strain measurements in bone mechanics: A critical review of current methods.J Mech Behav Biomed Mater. 2015 Oct;50:43-54. doi: 10.1016/j.jmbbm.2015.06.006. Epub 2015 Jun 11. J Mech Behav Biomed Mater. 2015. PMID: 26099201 Review.
-
Dentin bonding system. Part II: Effect of crosshead speed.Biomed Mater Eng. 1996;6(2):87-100. Biomed Mater Eng. 1996. PMID: 8761519 Review.
Cited by
-
Standardized tensile testing of soft tissue using a 3D printed clamping system.HardwareX. 2020 Nov 21;8:e00159. doi: 10.1016/j.ohx.2020.e00159. eCollection 2020 Oct. HardwareX. 2020. PMID: 35498242 Free PMC article.
-
The influence of different sample preparation on mechanical properties of human iliotibial tract.Sci Rep. 2020 Sep 9;10(1):14836. doi: 10.1038/s41598-020-71790-5. Sci Rep. 2020. PMID: 32908171 Free PMC article.
-
The Stress-Strain Data of the Hip Capsule Ligaments Are Gender and Side Independent Suggesting a Smaller Contribution to Passive Stiffness.PLoS One. 2016 Sep 29;11(9):e0163306. doi: 10.1371/journal.pone.0163306. eCollection 2016. PLoS One. 2016. PMID: 27685452 Free PMC article.
-
What is Considered a Variation of Biomechanical Parameters in Tensile Tests of Collagen-Rich Human Soft Tissues? - Critical Considerations Using the Human Cranial Dura Mater as a Representative Morpho-Mechanic Model.Medicina (Kaunas). 2020 Oct 5;56(10):520. doi: 10.3390/medicina56100520. Medicina (Kaunas). 2020. PMID: 33027931 Free PMC article.
-
Approach to Standardized Material Characterization of the Human Lumbopelvic System: Testing and Evaluation.Bioengineering (Basel). 2025 Aug 11;12(8):862. doi: 10.3390/bioengineering12080862. Bioengineering (Basel). 2025. PMID: 40868375 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources