The effect of radial preload on the implant-bone interface: a cadaveric study
- PMID: 2600701
- DOI: 10.1097/00005131-198912000-00012
The effect of radial preload on the implant-bone interface: a cadaveric study
Abstract
The most common complication of external fixation is pin loosening. Preloading the implant-bone interface is believed to retard this process. Radial preload, in particular, may be useful, as it allows loading in more than one direction. To investigate the effect of varying degrees of radial preload on the pin-bone interface, 30 freshly thawed human cadaveric tibiae were sectioned into 4-cm segments. Uniform drill holes were produced in the anterior tibial ridge of all segments and custom experimental bolts, oversized in diameter by as much as 1 mm, were pressed into each specimen. Macroscopic surface fractures were noted at the time of bolt insertion for misfits greater than 0.2 mm. Following histologic preparation, the implant-bone interface was evaluated microscopically based on the appearance of osteonal compression, lamellar distortion, and microfractures. Insertion of external fixator pins with misfits of greater than 0.4 mm resulted in significant microscopic structural damage to the bone surrounding the pin. High degrees of radial preload, exceeding the elastic limit of cortical bone, may be produced around pin holes by a small misfit. The use of oversized pins or screws must therefore be questioned.
Similar articles
-
Induction and prevention of pin loosening in external fixation: an in vivo study on sheep tibiae.J Orthop Trauma. 1991;5(4):485-92. doi: 10.1097/00005131-199112000-00017. J Orthop Trauma. 1991. PMID: 1762013
-
Axial preload in external fixator half-pins: a preliminary mechanical study of an experimental bone anchorage system.Clin Biomech (Bristol). 1999 Jan;14(1):69-73. doi: 10.1016/s0268-0033(98)00047-3. Clin Biomech (Bristol). 1999. PMID: 10619092
-
Analysis of the external fixator pin-bone interface.Clin Orthop Relat Res. 1993 Aug;(293):18-27. Clin Orthop Relat Res. 1993. PMID: 8339479
-
Increased insertion torque delays pin-bone interface loosening in external fixation with tapered bone screws.J Orthop Trauma. 2004 Oct;18(9):617-22. doi: 10.1097/00005131-200410000-00007. J Orthop Trauma. 2004. PMID: 15448451
-
Unicortical self-drilling external fixator pins reduce thermal effects during pin insertion.Eur J Trauma Emerg Surg. 2018 Dec;44(6):939-946. doi: 10.1007/s00068-017-0887-2. Epub 2017 Dec 14. Eur J Trauma Emerg Surg. 2018. PMID: 29242952 Free PMC article.
Cited by
-
Design and Evaluation of a Percutaneous Fragment Manipulation Device for Minimally Invasive Fracture Surgery.Front Robot AI. 2019 Oct 30;6:103. doi: 10.3389/frobt.2019.00103. eCollection 2019. Front Robot AI. 2019. PMID: 33501118 Free PMC article.
-
Pin-tract infection is an important factor associated with pin loosening during external fixation: a prospective analysis of 47 consecutive patients.Front Cell Infect Microbiol. 2025 Mar 27;15:1459205. doi: 10.3389/fcimb.2025.1459205. eCollection 2025. Front Cell Infect Microbiol. 2025. PMID: 40212847 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical