Circular anastomotic experimental fibrin sealant protection in deep colorectal anastomosis in pigs in a randomized 9-day survival study
- PMID: 26008730
- DOI: 10.1007/s00384-015-2260-4
Circular anastomotic experimental fibrin sealant protection in deep colorectal anastomosis in pigs in a randomized 9-day survival study
Abstract
Purpose: The reported rate of clinically apparent anastomotic leakage (AL) in a low anterior resection of the rectum (LAR) (≤7 cm from the anal verge) using a circular double-stapled anastomosis (CDSA) without defunctioning stoma is up to 37.5 %. Since AL may result in life-threatening peritonitis, sepsis, and multiple organ failure, LAR and CDSA are regularly combined with defunctioning stoma. Accordingly, we now evaluated whether LAR and CDSA without defunctioning stoma but with extraluminal anastomotic application of an experimental fibrin sealant reduce the AL rate. This might prevent humans from defunctioning stoma increasing quality of life and decreasing surgical costs.
Methods: Forty 8-week-old pigs underwent LAR and CDSA in an end-to-end technique (descendo-rectostomy). Animals were randomized into a therapy and control group (gr.). The therapy gr. (n = 20) received an additional extraluminal circular application of an experimental fibrin sealant to the anastomosis. The objective was to assess the incidence of clinically apparent and non-clinically apparent leakage through the ninth postoperative day. Double-contrast barium CT radiographs of the colorectal region were performed on the ninth postoperative day or earlier, in case there were clinical signs of AL. All remaining animals were sacrificed on the ninth postoperative day and the anastomotic region was histopathologically analyzed. In case of earlier diagnosed AL, animals were sacrificed immediately. Blood samples were taken for complete blood count, chemistry, and coagulation profile prior to surgery and on the first, third, fifth, seventh, and ninth postoperative day.
Results: A circular extraluminal anastomotic application of an experimental fibrin protection decreased the rate of clinically and non-clinically apparent AL from 20 % (n = 4) in the control group to 5 % (n = 1) in the treatment group. Ulcerations were also observed in both gr. (control gr.-5 animals, therapy gr. -3 animals). All animals with AL showed necrosis surrounding the hole at the anastomoses. Three additional animals had a full wall defect at the anastomotic region that was blocked by the experimental fibrin sealant. The fibrin sealant was present at necropsy in all treated animals.
Conclusion: Circular anastomotic protection with the experimental fibrin sealant blocked anastomotic full wall defects, preventing peritonitis and significantly reducing the AL rate from 25 to 5 %.
Similar articles
-
Is Circular Fibrin Sealing of Low Rectal Anastomosis Able to Prevent Leakage in 21-Day Follow-up? Randomized Experimental Trial in Pigs.Surg Innov. 2019 Aug;26(4):408-419. doi: 10.1177/1553350619834786. Epub 2019 May 4. Surg Innov. 2019. PMID: 31056009
-
A new anastomotic leakage model in circular double stapled colorectal anastomosis after low anterior rectum resection in pigs.J Invest Surg. 2013 Dec;26(6):364-72. doi: 10.3109/08941939.2013.818174. Epub 2013 Aug 19. J Invest Surg. 2013. PMID: 23957829
-
Sealing of gastrointestinal anastomoses with fibrin glue coated collagen patch.Dan Med J. 2015 May;62(5):B5081. Dan Med J. 2015. PMID: 26050838
-
Postoperative non-steroidal anti-inflammatory drugs and colorectal anastomotic leakage. NSAIDs and anastomotic leakage.Dan Med J. 2012 Mar;59(3):B4420. Dan Med J. 2012. PMID: 22381097 Review.
-
The potential effect of biological sealants on colorectal anastomosis healing in experimental research involving severe diabetes.Ann R Coll Surg Engl. 2017 Mar;99(3):189-192. doi: 10.1308/rcsann.2016.0357. Epub 2016 Dec 5. Ann R Coll Surg Engl. 2017. PMID: 27917665 Free PMC article. Review.
Cited by
-
Poly-ϵ-caprolactone scaffold as staple-line reinforcement of rectal anastomosis: an experimental piglet study.BMC Gastroenterol. 2024 Mar 15;24(1):112. doi: 10.1186/s12876-024-03202-1. BMC Gastroenterol. 2024. PMID: 38491416 Free PMC article.
-
Efficacy and Safety of Pleurodesis Using Platelet-Rich Plasma and Fibrin Glue in Management of Postoperative Chylothorax After Esophagectomy.World J Surg. 2018 Apr;42(4):1046-1055. doi: 10.1007/s00268-017-4242-x. World J Surg. 2018. PMID: 28986682 Clinical Trial.
-
Mucosa plication reinforced colorectal anastomosis and trans-anal vacuum drainage: a pilot study with preliminary results.Updates Surg. 2021 Dec;73(6):2145-2154. doi: 10.1007/s13304-021-01105-4. Epub 2021 Jun 5. Updates Surg. 2021. PMID: 34089500 Free PMC article.
-
New Technologies to Prevent Anastomotic Leak.Clin Colon Rectal Surg. 2021 Nov 23;34(6):379-384. doi: 10.1055/s-0041-1735268. eCollection 2021 Nov. Clin Colon Rectal Surg. 2021. PMID: 34853558 Free PMC article. Review.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous