. 2015 Jun 10;10(6):e0128929.
doi: 10.1371/journal.pone.0128929. eCollection 2015.

Axial Length Measurement Failure Rates with the IOLMaster and Lenstar LS 900 in Eyes with Cataract

Affiliations

Axial Length Measurement Failure Rates with the IOLMaster and Lenstar LS 900 in Eyes with Cataract

Colm McAlinden et al. PLoS One. .

Abstract

Purpose: To evaluate axial length (AL) measurement failure rate with the IOLMaster (Carl Zeiss AG, Germany) and Lenstar LS 900 (Haag-Streit AG, Switzerland) in eyes with cataract.

Methods: Two hundred and ninety-six eyes of 170 patients with cataract were enrolled. Cataract type and severity were graded using the Lens Opacities Classification System III (LOCS III) and AL measurements were attempted with IOLMaster (version 5.4) and Lenstar LS 900 (version 1.1). Chi-squared analysis was used to assess if the difference in AL measurement acquisition rate was statistically significant between the two devices. The association of the different cataract types and severity with the AL measurement acquisition rate was evaluated with logistic regression analysis.

Results: AL measurements were obtained in 184 eyes (62.16%) using the IOLMaster and 191 eyes (64.53%) using the Lenstar, which corresponds to a failure rate of 37.84% and 35.47% respectively. Chi-square analysis indicated no significant difference between the Lenstar and IOLMaster for AL measurement failure rate (x2 = 0.356, P = 0.550). Logistic regression analysis indicated no association between acquisition rates and cortical or nuclear cataracts with either device. There was a statistically significant association between acquisition rates and increasing severity of posterior subcapsular cataracts with the IOLMaster (β = -1.491, P<0.001) and Lenstar LS 900 (β = -1.507, P<0.001).

Conclusion: The IOLMaster and Lenstar LS 900 have similar AL measurement failure rates (35-38%) for Chinese public hospital cataract patients. Increasing severity of posterior subcapsular cataracts was problematic for both devices.

PubMed Disclaimer

Conflict of interest statement

Competing Interests: The authors have declared that no competing interests exist.

Figures

Fig 1
Fig 1. Failure rate in terms of percentage of eyes for the various cataract morphologies and LOCS III grading with the IOLMaster.
Fig 2
Fig 2. Failure rate in terms of percentage of eyes for the various cataract morphologies and LOCS III grading with the Lenstar LS 900.

References

    1. Micieli JA, Arshinoff SA (2011) Cataract surgery. CMAJ 183: 1621 10.1503/cmaj.110549 - DOI - PMC - PubMed
    1. Hodge W, Horsley T, Albiani D, Baryla J, Belliveau M, Buhrmann R, et al. (2007) The consequences of waiting for cataract surgery: a systematic review. CMAJ 176: 1285–1290. - PMC - PubMed
    1. Skiadaresi E, McAlinden C, Pesudovs K, Polizzi S, Khadka J, Ravalico G. (2012) Subjective quality of vision before and after cataract surgery. Arch Ophthalmol 130: 1377–1382. 10.1001/archophthalmol.2012.1603 - DOI - PubMed
    1. McAlinden C, Moore JE (2011) Multifocal intraocular lens with a surface-embedded near section: Short-term clinical outcomes. J Cataract Refract Surg 37: 441–445. 10.1016/j.jcrs.2010.08.055 - DOI - PubMed
    1. Nemeth J, Fekete O, Pesztenlehrer N (2003) Optical and ultrasound measurement of axial length and anterior chamber depth for intraocular lens power calculation. J Cataract Refract Surg 29: 85–88. - PubMed

Publication types