Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Feb;18(2):227-31.
doi: 10.1093/europace/euv188. Epub 2015 Jun 10.

Incidence of and predictors for appropriate implantable cardioverter-defibrillator therapy in patients with a secondary preventive implantable cardioverter-defibrillator indication

Affiliations

Incidence of and predictors for appropriate implantable cardioverter-defibrillator therapy in patients with a secondary preventive implantable cardioverter-defibrillator indication

Beat Schaer et al. Europace. 2016 Feb.

Abstract

Aims: Incidence of implantable cardioverter-defibrillator (ICD) therapy in secondary prevention has been assessed in randomized trials and registries. However, results are considerably limited by short follow-up and hazy definition of treated arrhythmias. This study aimed to determine appropriate ICD therapy and to define predictors based on registry patients followed for up to 20 years.

Methods and results: All patients with a secondary prevention indication and ischaemic or dilated cardiomyopathy were identified. Arrhythmic endpoints were appropriate ICD therapies for any ventricular tachycardia (VT) >175 b.p.m. and appropriate ICD therapies in the ventricular fibrillation (VF) zone of >220 b.p.m. (potentially life-threatening). Predictors were determined by analysing 19 baseline characteristics. We included 357 patients, age 65 ± 11 years, predominantly male (89%) with ischaemic cardiomyopathy (83%). During follow-up of 82 ± 53 months, 156 (44%) patients died and 208 received any form of ICD therapies (59%), 71 of them (34%) in the VF zone. Forty-four patients (28%) died without experiencing any form of appropriate ICD therapy. Cumulative incidence of any form of ICD therapy at 10 years was 65%. Predictors for any form of ICD therapy were implantation for VT and age [VT: hazard ratio (HR) 1.45, 95% confidence interval (95% CI) 1.05-2.01, P = 0.03; age (per year): HR 1.02, 95% CI 1.01-1.04, P = 0.001]. For therapy in the VF zone, univariate analysis determined male gender (29 vs. 5%, P = 0.01) as predictor.

Conclusion: The rate of appropriate ICD therapies in secondary prevention is high. No useful predictors for them, especially not for life-threatening arrhythmias could be identified.

Keywords: Cumulative incidence; Implantable cardioverter-defibrillator; Predictor; Secondary prevention.