. 2015 Jun;35(3):432-438.
doi: 10.1007/s11596-015-1449-7. Epub 2015 Jun 14.

Comparison of cardiac output and hemodynamic responses of intubation among different videolaryngoscopies in normotensive and hypertensive patients

Affiliations
Comparative Study

Comparison of cardiac output and hemodynamic responses of intubation among different videolaryngoscopies in normotensive and hypertensive patients

Amro Faez Abdelgawad et al. J Huazhong Univ Sci Technolog Med Sci. 2015 Jun.

Abstract

Tracheal intubation with Macintosh laryngoscope (MAC) might result in severe cardiovascular complications. The results of conducted studies investigating the effects of videolaryngoscopies on hemodynamic response of tracheal intubation are conflicting. We know little about the effects of videolaryngoscopies on cardiac output changes during tracheal intubation. We compared cardiac output (COP) and hemodynamic responses in normal blood pressure (n=60) and hypertensive patients (n=60) among 3 intubation devices: the MAC, the UE videolaryngoscopy ® (UE), and the UE video intubation stylet ® (VS). Cardiac index (CI), stroke volume index (SVI), heart rate (HR), systolic blood pressure (SBP) and diastolic blood pressure (DBP) were recorded using LidcoRapid (V2)® preinduction, preintubation, and every minute for the first 5 min after intubation. We assessed oropharyngeal and laryngeal structures injury as well. Intubation time was significantly shorter than MAC groups (P<0.001) only in UE group of normotensive and hypertensive patients. In normotensive patients, there were no significant differences in any of COP variables or hemodynamic variables among the three devices. In hypertensive patients, SBP and DBP in the MAC group were significantly higher (P<0.05 or <0.01) than the UE and VS groups at 1, 2 and 3 min after intubation, but there were no significant differences in CI, SVI and HR among the three devices. There was no significant difference in oropharyngeal and laryngeal structures injury among all groups. It was concluded that both the UE and VS attenuate only the hemodynamic response to intubation as compared with the MAC in hypertensive patients, but not in normotensive patients.

PubMed Disclaimer

References

    1. J Clin Anesth. 2008 Jun;20(4):257-62 - PubMed
    1. Br J Anaesth. 2013 Dec;111(6):990-5 - PubMed
    1. Anesthesiology. 1979 Apr;50(4):285-92 - PubMed
    1. Anesthesiology. 1977 Dec;47(6):524-5 - PubMed
    1. Anaesthesia. 1984 Nov;39(11):1105-11 - PubMed

Publication types

MeSH terms

LinkOut - more resources