Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2015 Oct;8(5):1017-29.
doi: 10.1161/CIRCEP.115.003019. Epub 2015 Jun 16.

Is There Still a Role for Complex Fractionated Atrial Electrogram Ablation in Addition to Pulmonary Vein Isolation in Patients With Paroxysmal and Persistent Atrial Fibrillation? Meta-Analysis of 1415 Patients

Affiliations
Meta-Analysis

Is There Still a Role for Complex Fractionated Atrial Electrogram Ablation in Addition to Pulmonary Vein Isolation in Patients With Paroxysmal and Persistent Atrial Fibrillation? Meta-Analysis of 1415 Patients

Rui Providência et al. Circ Arrhythm Electrophysiol. 2015 Oct.

Abstract

Background: Ablation of complex fractionated atrial electrograms (CFAEs) has been proposed as a strategy to improve outcomes in atrial fibrillation (AF) catheter ablation, but the use of this technique remains contentious. We aimed to assess the impact of CFAE ablation in addition to pulmonary vein isolation (PVI) in patients undergoing ablation for AF.

Methods and results: We performed a random effects meta-analysis of studies comparing PVI versus PVI+CFAE ablation. The outcomes of freedom from AF/atrial tachycardia after 1 or several ablation procedures and acute procedural-related complications were assessed. Studies were searched on MEDLINE, EMBASE, COCHRANE, and clinicaltrials.gov, and sensitivity analyses were performed. Thirteen studies including a total of 1415 patients were considered eligible. Additional ablation of CFAEs resulted in no improvement in mid-term procedural outcome or freedom from AF or atrial tachycardia (odds ratio [OR], 0.80; 95% confidence interval [CI], 0.58-1.10; P=0.17). Sensitivity analysis of 398 paroxysmal AF ablation procedures showed no incremental benefit of CFAE ablation (OR, 0.80; 95% CI, 0.46-1.38; P=0.42). PVI+CFAE ablation versus PVI alone did not improve the overall rate of freedom from AF or atrial tachycardia in patients with persistent AF (OR, 1.01; 95% CI, 0.63-1.64; P=0.96) or longstanding persistent AF (OR, 0.84; 95% CI, 0.24-2.96; P=0.79). There was no increase in procedural-related adverse events (OR, 1.06; 95% CI, 0.41-2.75; P=0.91).

Conclusions: Despite the apparent safety of this technique, CFAE ablation did not improve freedom from AF/atrial tachycardia in patients with paroxysmal or persistent AF. The role of CFAE ablation in addition to PVI should be questioned and other alternatives assessed to improve the outcome of AF ablation.

Keywords: atrial fibrillation; catheter ablation; electrophysiology; pulmonary veins; tachycardia.

PubMed Disclaimer

Comment in

Publication types

MeSH terms