The diagnostic accuracy of magnetic resonance venography in the detection of deep venous thrombosis: a systematic review and meta-analysis
- PMID: 26091753
- DOI: 10.1016/j.crad.2015.04.007
The diagnostic accuracy of magnetic resonance venography in the detection of deep venous thrombosis: a systematic review and meta-analysis
Abstract
Aim: To search the literature for further evidence for the use of magnetic resonance venography (MRV) in the detection of suspected DVT and to re-evaluate the accuracy of MRV in the detection of suspected deep vein thrombosis (DVT).
Materials and methods: PubMed, EMBASE, Scopus, Cochrane, and Web of Science were searched. Study quality and the risk of bias were evaluated using the QUADAS 2. A random effects meta-analysis including subgroup and sensitivity analyses were performed.
Results: The search resulted in 23 observational studies all from academic centres. Sixteen articles were included in the meta-analysis. The summary estimates for MRV as a diagnostic non-invasive tool revealed a sensitivity of 93% (95% confidence interval [CI]: 89% to 95%) and specificity of 96% (95% CI: 94% to 97%). The heterogeneity of the studies was high. Inconsistency (I2) for sensitivity and specificity was 80.7% and 77.9%, respectively.
Conclusion: Further studies investigating the use of MRV in the detection of suspected DVT did not offer further evidence to support the replacement of ultrasound with MRV as the first-line investigation. However, MRV may offer an alternative tool in the detection/diagnosis of DVT for whom ultrasound is inadequate or not feasible (such as in the obese patient).
Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.