Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Sep;26(9):1494-501.
doi: 10.1007/s13361-015-1171-5. Epub 2015 Jun 20.

Multistage Reactive Transmission-Mode Desorption Electrospray Ionization Mass Spectrometry

Affiliations

Multistage Reactive Transmission-Mode Desorption Electrospray Ionization Mass Spectrometry

Kevin C Peters et al. J Am Soc Mass Spectrom. 2015 Sep.

Abstract

Elucidating reaction mechanisms is important for advancing many areas of science such as catalyst development. It is often difficult to probe fast reactions at ambient conditions with high temporal resolution. In addition, systems involving reagents that cross-react require analytical methods that can minimize interaction time and specify their order of introduction into the reacting system. Here, we explore the utility of transmission mode desorption electrospray ionization (TM-DESI) for reaction monitoring by directing a microdroplet spray towards a series of meshes with micrometer-sized openings coated with reagents, an approach we call multistage reactive TM-DESI (TM (n) -DESI, where n refers to the number of meshes; n = 2 in this report). Various stages of the reaction are initiated at each mesh surface, generating intermediates and products in microdroplet reaction vessels traveling towards the mass spectrometer. Using this method, we investigated the reactivity of iron porphyrin catalytic hydroxylation of propranolol and other substrates. Our experimental results indicate that TM (n) -DESI provides the ability to spatially separate reagents and control their order of introduction into the reacting system, thereby minimizing unwanted reactions that lead to catalyst deactivation and degradation products. In addition, comparison with DESI-MS analyses (the Zare and Latour laboratories published results suggesting accessible reaction times <1 ms) of the reduction of dichlorophenolindophenol by L-ascorbic acid suggest that TM (1) -DESI can access reaction times less than 1 ms. Multiple meshes allow sequential stages of desorption/ionization per MS scan, increasing the number of analytes and reactions that can be characterized in a single experiment.

PubMed Disclaimer

Comment in

References

    1. Angew Chem Int Ed Engl. 2014 Feb 3;53(6):1580-4 - PubMed
    1. J Am Chem Soc. 2013 Sep 25;135(38):14299-305 - PubMed
    1. Anal Chem. 2010 May 15;82(10):4130-9 - PubMed
    1. Analyst. 2010 Apr;135(4):669-81 - PubMed
    1. J Am Soc Mass Spectrom. 2012 Jun;23(6):1077-84 - PubMed

Publication types

MeSH terms

LinkOut - more resources