Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Jan-Feb;18(1):114-7.
doi: 10.4103/1008-682X.154311.

Implantation of AMS 700 LGX penile prosthesis preserves penile length without the need for penile lengthening procedures

Affiliations

Implantation of AMS 700 LGX penile prosthesis preserves penile length without the need for penile lengthening procedures

Carlo Luigi Augusto Negro et al. Asian J Androl. 2016 Jan-Feb.

Abstract

Implantation of an inflatable penile prosthesis (IPP) is a well-established definitive solution for erectile dysfunction when conservative treatments fail. Penile implants may shorten the penis. The AMS 700 LGX IPP is in common use but reports on its mechanical reliability, medium-term postsurgical patient satisfaction, and mean penile length preservation are lacking. We investigate the mean penile length, mechanical reliability, and patient satisfaction at 6 and 12 months after implantation of the AMS 700 LGX. This prospective study consecutively enrolled men undergoing first-time IPP implant surgery from February 2009 to April 2012. Stretched flaccid penile length, penile length at 50% and 100% of stiffness (P50 and P100) and International Index of Erectile Function (IIEF) and Erectile Dysfunction Inventory of Treatment Satisfaction (EDITS) scores, were measured at 6 and 12 months postsurgery. Of 45 patients who underwent AMS 700 LGX implantation (median age 61 years) and completed 6 months' follow-up, 36 (80%) completed the study. A significant difference in stretched flaccid penile length was seen between 6 and 12 months (P = 0.033). P100 was also significantly increased at 6 and 12 months, with a mean 10% increase (1.3 ± 0.4 cm) from baseline to 12 months. Differences in mean IIEF scores at 6 and 12 months were significant for the desired domain (P = 0.0001) and for overall satisfaction (P = 0.002); however, mean EDITS scores at 6 and 12 months were not significantly improved. AMS 700 LGX is a powerful tool for preserving penile length in men undergoing penile prosthesis implantation.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Penile length (stretched, P50 and P100) at baseline and at 6 and 12 months after surgery. *and **statistically significant differences (P < 0.05).
Figure 2
Figure 2
Variation in International Index of Erectile Function (IIEF) scores at 6 and 12 months. **Statistically significant differences (P < 0.05).

References

    1. Rajpurkar A, Dhabuwala CB. Comparison of satisfaction rates and erectile function in patients treated with sildenafil, intracavernous prostaglandin E1 and penile implant surgery for erectile dysfunction in urology practice. J Urol. 2003;170:159–63. - PubMed
    1. Jain S, Bhojwani A, Terry TR. The role of penile prosthetic surgery in the modern management of erectile dysfunction. Postgrad Med J. 2000;76:22–5. - PMC - PubMed
    1. Furlow WL, Goldwasser B, Gundian JC. Implantation of model AMS 700 penile prosthesis: long-term results. J Urol. 1988;139:741–2. - PubMed
    1. Deveci S, Martin D, Parker M, Mulhall JP. Penile length alterations following penile prosthesis surgery. Eur Urol. 2007;51:1128–31. - PubMed
    1. Montague DK, Lakin MM. Early experience with the controlled girth and length expanding cylinder of the American Medical Systems Ultrex penile prosthesis. J Urol. 1992;148:1444–6. - PubMed