Multicenter Study
. 2015 Jul;8(8):1105-1112.
doi: 10.1016/j.jcin.2015.03.022. Epub 2015 Jun 24.

1-Year Results of the ZEPHYR Registry (Zilver PTX for the Femoral Artery and Proximal Popliteal Artery): Predictors of Restenosis

Affiliations
Free article
Multicenter Study

1-Year Results of the ZEPHYR Registry (Zilver PTX for the Femoral Artery and Proximal Popliteal Artery): Predictors of Restenosis

Osamu Iida et al. JACC Cardiovasc Interv. 2015 Jul.
Free article

Abstract

Objectives: This study sought to assess the rate and predictors of 1-year restenosis after drug-eluting stent implantation for femoropopliteal (FP) lesions in patients with peripheral arterial disease.

Background: Zilver PTX, a paclitaxel-eluting stent for FP lesions, provides superior outcomes to angioplasty and bare-metal stents in clinical trials. However, its real-world outcomes and the associated features remain unclear.

Methods: This was a prospective multicenter study enrolling 831 FP lesions (797 limbs, 690 patients) treated by Zilver PTX implantation. The primary endpoint was 1-year restenosis. Secondary endpoints included major adverse limb event and stent thrombosis.

Results: Mean lesion length was 17 ± 10 cm. One-year restenosis, major adverse limb event, and stent thrombosis rates were 37%, 22%, and 2%, respectively. The generalized linear mixed model showed that lesion length ≥16 cm assessed by angiography and distal external elastic membrane area ≤27 mm(2) and minimum stent area ≤12 mm(2) assessed by intravascular ultrasound were independent risk factors for restenosis. One-year restenosis rates were 15% in cases with none of these risk factors and 50% in those with ≥2 risk factors.

Conclusions: The current study demonstrated 1-year real-world outcomes after drug-eluting stent treatment for FP lesions, including challenging ones in clinical practice. Lesion length, external elastic membrane area, and minimum stent area were independent predictors for restenosis. (Zilver PTX for the Femoral Artery and Proximal Popliteal Artery-Prospective Multicenter Registry [ZEPHYR]; UMIN000008433).

Keywords: drug-eluting stent; endovascular therapy; femoropopliteal lesion; intravascular ultrasound; restenosis.