Acoustic micromixing increases antibody-antigen binding in immunoassays
- PMID: 26162483
- DOI: 10.1007/s10544-015-9987-0
Acoustic micromixing increases antibody-antigen binding in immunoassays
Abstract
Sound wave-assisted acoustic micromixing has been shown to increase the binding of molecules in small volumes (10-100 μL) where effective mixing is difficult to achieve through conventional techniques. The aim of this work is to study whether acoustic micromixing can increase the binding efficiency of antibodies to their antigens, a reaction that forms the basis of immunoassays, including enzyme-linked immunosorbent assay (ELISA). Using a procedure from a general ELISA and immobilizing an antigen on wells of 96-well plates, it was found that acoustic micromixing at 125-150 Hz increased the initial rate of antibody-antigen binding by over 80 % and the total binding at the end point (i.e., 45 min) by over 50 %. As a result, acoustic micromixing achieved a binding level in 9 min that would otherwise take 45 min on a standard platform rocking mixer. Therefore acoustic micromixing has the potential to increase the detection sensitivity of ELISA as well as shorten the antigen-antibody binding times from typically 45-60 min to 15 min.
Similar articles
-
Overprint immunoassay using protein A microarrays.Methods Mol Biol. 2007;382:273-86. doi: 10.1007/978-1-59745-304-2_18. Methods Mol Biol. 2007. PMID: 18220238
-
Gas phase activity of anti-FITC antibodies immobilized on a surface acoustic wave resonator device.Biosens Bioelectron. 2002 Jun;17(6-7):471-7. doi: 10.1016/s0956-5663(01)00318-9. Biosens Bioelectron. 2002. PMID: 11959467
-
Electrophoresis-assisted active immunoassay.Anal Chem. 2003 Dec 15;75(24):6813-9. doi: 10.1021/ac034733o. Anal Chem. 2003. PMID: 14670040
-
The use of immunochemical and biosensor methods for occupational and environmental monitoring. Part I: introduction to immunoassays.J Occup Environ Hyg. 2008 Feb;5(2):D25-32. doi: 10.1080/15459620701798182. J Occup Environ Hyg. 2008. PMID: 18074291 Review. No abstract available.
-
Allowance for antibody bivalence in the characterization of interactions by ELISA.J Mol Recognit. 2011 Mar-Apr;24(2):139-48. doi: 10.1002/jmr.1054. Epub 2010 Aug 25. J Mol Recognit. 2011. PMID: 20740505 Review.
Cited by
-
Surface Acoustic Wave-Driven Enhancement of Enzyme-Linked Immunosorbent Assays: ELISAW.Anal Chem. 2024 Jun 11;96(23):9676-9683. doi: 10.1021/acs.analchem.4c01615. Epub 2024 May 30. Anal Chem. 2024. PMID: 38813952 Free PMC article.
-
Manipulation with sound and vibration: A review on the micromanipulation system based on sub-MHz acoustic waves.Ultrason Sonochem. 2023 Jun;96:106441. doi: 10.1016/j.ultsonch.2023.106441. Epub 2023 May 13. Ultrason Sonochem. 2023. PMID: 37216791 Free PMC article. Review.
-
Cryo-EM structure of a human prion fibril with a hydrophobic, protease-resistant core.Nat Struct Mol Biol. 2020 May;27(5):417-423. doi: 10.1038/s41594-020-0403-y. Epub 2020 Apr 13. Nat Struct Mol Biol. 2020. PMID: 32284600 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials