Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2015 Oct;100(4):1334-9.
doi: 10.1016/j.athoracsur.2015.04.003. Epub 2015 Jul 7.

Endoaortic Clamping Does Not Increase the Risk of Stroke in Minimal Access Mitral Valve Surgery: A Multicenter Experience

Affiliations
Multicenter Study

Endoaortic Clamping Does Not Increase the Risk of Stroke in Minimal Access Mitral Valve Surgery: A Multicenter Experience

Filip Casselman et al. Ann Thorac Surg. 2015 Oct.

Abstract

Background: Some controversy exists regarding the safety of endoaortic balloon clamping in minimal access isolated mitral valve surgery (MIMVS). The aim of this European multicenter study was to analyze the results in 10 experienced centers and compare the outcomes with published data.

Methods: The most recent 50 consecutive MIMVS cases from 10 European surgeons who had performed at least 100 procedures were prospectively collected and retrospectively analyzed. All procedures were performed through right minithoracotomy with femoral cannulation and endoaortic balloon occlusion. In-hospital and 30-day outcomes were studied. Mortality and stroke rates were compared with published median sternotomy and MIMVS outcomes.

Results: Mean age was 63.2 ± 12.5 years, 289 (57.8%) were male, mean logistic European system for cardiac operative risk evaluation was 6.1 ± 6.2, and 53 (10.6%) procedures had cardiac reoperations. Concomitant procedures were performed in 126 (25.9%) cases. Three patients (0.6%) required conversion to full sternotomy. Ten patients (2.0%) necessitated endoaortic balloon clamping conversion (8 to external clamping), and re-exploration for bleeding was necessary in 24 (4.8%) cases. Mean aortic cross-clamp and cardiopulmonary bypass times were 85.6 ± 30.1 and 129.5 ± 40.2 min, respectively, and were significantly longer for concomitant procedures (p < 0.001). There were no aortic dissections and no deep venous thromboses. Operative mortality (none neurologic) and major stroke occurred in 7 (1.4%) and 4 (0.8%) patients, respectively. These rates compared favorably with the published literature on isolated primary mitral valve surgery (MVS) through sternotomy or minithoracotomy (mortality rates 0.2% to 11.6%, stroke rates 0.6% to 4.4%).

Conclusions: Once procedural proficiency is acquired, endoaortic balloon clamping in MIMVS is a safe and effective technique. Despite the fact that this patient cohort also includes combined and redo procedures, the observed mortality and stroke rate compared favorably with the existing literature on primary isolated mitral valve surgery irrespective of the approach.

PubMed Disclaimer

Publication types

LinkOut - more resources